3M X62 User Manual - Page 48

Using the Transition Detector Function, Transition Detector, Description, SECURITY, 1 Turning On

Page 48 highlights

3M™ Digital Projector X62 OPTION Menu OPTION Menu (continued) Item SECURITY 48 Description 4. Using the Transition Detector Function While the Transition Detector function is ON, when power switch is started to supply to the projector, it might react as below. • Transition Detector alarm shown below might appear on screen, if the projector has been moved or re-installed. • Transition Detector alarm might appear on screen, if the MIRROR setting has been changed. • Keystone adjustment feature has been prohibited as long as the Transition Detector function is ON. 4.1 Turning On the Transition Detector Function 4.1-1 8VHWKHŸźEXWWRQVRQWKH6(&85,7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64

48
Item
Description
SECURITY
4. Using the Transition Detector Function
While the Transition Detector function is ON, when power switch is started to
supply to the projector, it might react as below.
• Transition Detector alarm shown below might appear on screen, if the
projector has been moved or re-installed.
• Transition Detector alarm might appear on screen, if the MIRROR setting
has been changed.
• Keystone adjustment feature has been prohibited as long as the Transition
Detector function is ON.
4.1 Turning On the
Transition Detector
Function
4.1-1
ENTER button to display the Transition Detector
on/off menu. Select TURN ON and the current
angle, mirror and keystone setting will be recorded.
NOTE: This feature may not function properly if the projector
is not in a stable position when TURN ON is selected.
4.1-2
If this function is set to TURN ON when
the vertical angle of the projector, mirror or
keystone setting at which the projector is
turned on is different than the previously
recorded the Transition Detector Alarm will be
displayed and the projector will not display the
input signal.
Either set the Transition Detector off in the SECURITY menu or set the projector at
the recorded angle, mirror and keystone setting to display the input signal.
If the Transition Detector ALARM is displayed for about 5 minutes the lamp will turn off.
This function will activate only when the projector is started after the power
switch was turned off.
4.2 Setting the
Transition Detector
PASSWORD
4.2-1
Transition
Detector
Transition
Detector
on/off menu.
4.2-2
on/off menu to select TURN ON. The ENTER
PASSWORD BOX (small) will be displayed.
4.2-3
Move the cursor to the right side of the ENTER
to display the CHECK PASSWORD BOX, enter the
same PASSWORD again.
4.2-4
Move the cursor to the right side of the CHECK
display the PASSWORD for about 20 seconds,
please make note of the PASSWORD during
this time. After the PASSWORD has displayed
for about 20 seconds the screen will return to
the Transition Detector on/off menu.
Pressing the ENTER button on the remote controll or the INPUT button on
the projector will close the PASSWORD BOX.
NOTE
: Please do not forget your Transition Detector PASSWORD.
OPTION Menu (continued)
OPTION Menu
Transition Detector
on/off menu
Transition Detector
Alarm
ENTER PASSWORD
BOX (small)
CHECK PASSWORD
BOX
PASSWORD BOX
3M™ Digital Projector X62
© 3M 2006.