Adaptec 2410SA User Guide - Page 135

enclosure show fan [{enclosure}] [{fan}], enclosure set scsiid {enclosure} {slot} {device_ID}

Page 135 highlights

Command Line Interface (CLI) enclosure set power [/off{=boolean}] {enclosure} {powersupply} Turns on or off a specific power supply. Parameters {enclosure}-ID associated with the enclosure management device. {powersupply}-Unit number associated with the power supply. Switches /off-Specifies whether to turn on or off the power supply associated with the unit number. enclosure set scsiid {enclosure} {slot} {device_ID} Sets the ID of the device slot. Parameters {enclosure}-ID associated with the enclosure management device. {slot}-Unit number associated with the device slot to assign a channel number. {device_ID}-ID of the device. enclosure set temperature {enclosure} {degree} Sets the temperature threshold. Parameters {enclosure}-ID associated with the enclosure management device on which to set a temperature threshold. {degree}-Temperature (in degrees Fahrenheit from 0 to 255). enclosure show fan [{enclosure}] [{fan}] Displays the status of a specific fan. Parameters {enclosure}-ID associated with the enclosure management device for which to display fan status. {fan}-Unit number associated with the fan. C-36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153

C-36
Command Line Interface (CLI)
enclosure set power [/off{=boolean}] {enclosure}
{powersupply}
Turns on or off a specific power supply.
Parameters
{enclosure}
ID associated with the enclosure management
device.
{powersupply}
Unit number associated with the power
supply.
Switches
/off
Specifies whether to turn on or off the power supply
associated with the unit number.
enclosure set scsiid {enclosure} {slot} {device_ID}
Sets the ID of the device slot.
Parameters
{enclosure}
ID associated with the enclosure management
device.
{slot}
Unit number associated with the device slot to assign a
channel number.
{device_ID}
ID of the device.
enclosure set temperature {enclosure} {degree}
Sets the temperature threshold.
Parameters
{enclosure}
ID associated with the enclosure management
device on which to set a temperature threshold.
{degree}
Temperature (in degrees Fahrenheit from 0 to 255).
enclosure show fan [{enclosure}] [{fan}]
Displays the status of a specific fan.
Parameters
{enclosure}
ID associated with the enclosure management
device for which to display fan status.
{fan}
Unit number associated with the fan.