Electrical Connection
UPC - 883049137407
View all Amana AEP222VAW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
Power Supply Cord Electrical Connection Direct Wire WARNING WARNING Electrical Shock Hazard Disconnect power before servicing. Use a new 40 amp power supply cord. Plug into a grounded outlet. Failure to follow these instructions can result in death, fire, or electrical shock. Electrical Shock Hazard Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Electrically ground range. Failure to follow these instructions can result in death, fire, or electrical shock. 1. Disconnect power 2. Remove the terminal block cover screws located on the back of the range. Pull cover down and toward you to remove cover. ■ Tighten strain relief screw against the power supply cord. A. Hold-down screws B. Terminal block cover 3. Add strain relief. Style 1: Power supply cord strain relief ■ Assemble a UL listed strain relief in the opening. A B A. UL listed strain relief - large opening B. Small opening ■ Feed the power supply cord through the strain relief on the cord/conduit plate on bottom of range. Allow enough slack to easily attach the wiring to the terminal block. Style 2: Direct wire strain relief ■ Use Phillips screwdriver to remove screws and rotate/ conduit plate 180º. A B A. Large opening B. Small opening ■ Position cord/conduit plate as shown in the following illustration. B A A. Small opening B. Large opening 7