Page 41 highlights

User-maintenance instructions Exhaust requirements and instructions: 1. Venting materials are not provided with the dryer and you should obtain the necessary venting materials. For example, the outer end of exhaust pipe must have a weather hood with hinged dampers to prevent back draft when the dryer is not in use. 2. The exhaust duct must be four inches (10.2 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. 3. Rigid or semi-rigid metal ducting is recommended for use as transition ducting between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, then a U.L.-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect dry time. 4. DO NOT use sheet metal screws on exhaust pipe joints or other fastening means which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. 5. To maximize operating results, please observe the duct length limitations noted in the chart on page 36. Exhaust and dryer maintenance Caution! Disconnect the dryer's electric power prior to any cleaning or maintenance. 1. After one year of use, the interior and complete exhaust system of the dryer should be examined and cleaned if necessary. 2. Before one year of use, when drying performance has become unsatisfactory, please examine and clean the exhaust duct for better drying performance. 3. Check the weather hoods frequently to ensure the dampers are moving freely, that the dampers are not pushed in and that nothing has been set against the dampers. 4. A qualified service person or company should be used to perform this maintenance. 5. A Flexible Metal Vent Kit, sold separately at home improvement store, can be used to exhaust the dryer when it is placed in hard to reach location. This Kit comes in two pieces, one to attach on the dryer and the other to attach on the wall exhaust outlet. After attaching two separate pieces to the dryer and the wall, the dryer may be returned to its final position, after which the two pieces themselves can be connected. 6. Ordinarily, the dryer drum will need no care. Wipe the exterior of the dryer as required, and always wipe the exterior of the dryer in the event any detergent, bleach, or other washing products is spilled on the dryer. 7. Clean the control panel with a damp cloth as necessary. Warning: spray prewash products may damage the finish of the control panel. 8. Please clean the lint filter either before drying each load or after drying each load. 9. Always make sure the lint filter is clean before starting a new load, because a clogged lint filter may increase drying times. 10. Please note that the wiring diagram is provided inside the dryer control hood. Label all wires prior to disconnection when servicing the dryer, because wiring errors can cause serious injury to you and your dryer. Customer Care Center 41 1-800-898-1879 www.askousa.com

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47

41
Customer Care Center
1-800-898-1879
www.askousa.com
User-maintenance instructions
Exhaust requirements and
instructions:
Venting materials are not provided
1.
with the dryer and you should obtain
the necessary venting materials. For
example, the outer end of exhaust pipe
must have a weather hood with hinged
dampers to prevent back draft when the
dryer is not in use.
The exhaust duct must be four
2.
inches (10.2 cm) in diameter with no
obstructions. The exhaust duct should
be kept as short as possible. Make sure
to clean any old ducts before installing
your new dryer.
Rigid or semi-rigid metal ducting is
3.
recommended for use as transition
ducting between the dryer and the
wall. In special installations when it is
impossible to make a connection with
the above recommendations, then a
U.L.-listed flexible metal transition duct
may be used between the dryer and wall
connection only. The use of this ducting
will affect dry time.
DO NOT use sheet metal screws on
4.
exhaust pipe joints or other fastening
means which extend into the duct that
could catch lint and reduce the efficiency
of the exhaust system. Secure all joints
with duct tape.
To maximize operating results, please
5.
observe the duct length limitations noted
in the chart on page 36.
Exhaust and dryer maintenance
Caution!
Disconnect the dryer’s electric power prior to
any cleaning or maintenance.
After one year of use, the interior and
1.
complete exhaust system of the dryer
should be examined and cleaned if
necessary.
Before one year of use, when drying
2.
performance has become unsatisfactory,
please examine and clean the exhaust
duct for better drying performance.
Check the weather hoods frequently to
3.
ensure the dampers are moving freely,
that the dampers are not pushed in and
that nothing has been set against the
dampers.
A qualified service person or company
4.
should be used to perform this
maintenance.
A Flexible Metal Vent Kit, sold separately
5.
at home improvement store, can be
used to exhaust the dryer when it is
placed in hard to reach location. This
Kit comes in two pieces, one to attach
on the dryer and the other to attach on
the wall exhaust outlet. After attaching
two separate pieces to the dryer and
the wall, the dryer may be returned to its
final position, after which the two pieces
themselves can be connected.
Ordinarily, the dryer drum will need no
6.
care. Wipe the exterior of the dryer as
required, and always wipe the exterior
of the dryer in the event any detergent,
bleach, or other washing products is
spilled on the dryer.
Clean the control panel with a damp
7.
cloth as necessary. Warning: spray pre-
wash products may damage the finish of
the control panel.
Please clean the lint filter either before
8.
drying each load or after drying each
load.
Always make sure the lint filter is clean
9.
before starting a new load, because a
clogged lint filter may increase drying times.
Please note that the wiring diagram is
10.
provided inside the dryer control hood.
Label all wires prior to disconnection when
servicing the dryer, because wiring errors
can cause serious injury to you and your
dryer.