Asus ROG STRIX X670E-I GAMING WIFI ROG STRIX X670E Series BIOS Manual English - Page 29

AI Features, Level 3 Action Value

Page 29 highlights

Algorithm 1-3 Action Select the action to take when targeted condition crosses the threshold. When multiple Algorithms execute the same Actions, then the result is 'AND' and the smaller of the 2 Action Values get written. Configuration options: [Auto] [Package Power Limit Fast] [Package Power Limit Slow] [Thermal Limit] [Vcore TDC Limit] [Vcore EDC Limit] [SOC TDC Limit] [SOC EDC Limit] [ECLK ASynch BCLK] Level 1 Threshold Value Set the boundary separating the Level1 Action Value and Level2 Action Value. When condition is below or equal to this value, then Level1 Action Value gets written. If above but below Level2 Threshold Value, then Level2 Action Value gets written. Temperature is in degrees Celsius, Voltage is in millivolts, and current is in Ampere. Configuration options: [Auto] [0] - [65000] Level 2 Threshold Value Set the boundary separating the Level2 Action Value and Level3 Action Value. When condition is below or equal to this value and above Level1 Threshold Value, then Level2 Action Value gets written. If above, then Level3 Action Value gets written. Temperature is in degrees Celsius, Voltage is in millivolts, and current is in Ampere. Configuration options: [Auto] [0] - [65000] Level 1 Action Value Set the value for Action to take when condition lies below the first boundary. Power in Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is in MHz. Configuration options: [Auto] [0] - [65000] Level 2 Action Value Set the value for Action to take when condition lies between the first boundary and second boundary. Power in Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is in MHz. Configuration options: [Auto] [0] - [65000] Level 3 Action Value Set the value for Action to take when condition lies above the second boundary. Power in Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is in MHz. Configuration options: [Auto] [0] - [65000] AI Features Allows you to configure AI features. Cooler Efficiency Customize [Keep Training] Continuous evaluations will be performed on Cooler efficiency and updated accordingly. [Stop Training] Cooler efficiency evaluations will stop and current evaluated efficiency will be used. [User Specify] You can specify the Cooler efficiency manually and all predictions will be based off this manual setting. ROG STRIX X670E Series BIOS Manual 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98

ROG STRIX X670E Series BIOS Manual
29
Algorithm 1-3 Action
Select the action to take when targeted condition crosses the threshold. When
multiple Algorithms execute the same Actions, then the result is ‘AND’ and the smaller
of the 2 Action Values get written.
Configuration options: [Auto] [Package Power Limit Fast] [Package Power Limit Slow]
[Thermal Limit] [Vcore TDC Limit] [Vcore EDC Limit] [SOC TDC Limit] [SOC EDC
Limit] [ECLK ASynch BCLK]
Level 1 Threshold Value
Set the boundary separating the Level1 Action Value and Level2 Action Value. When
condition is below or equal to this value, then Level1 Action Value gets written. If
above but below Level2 Threshold Value, then Level2 Action Value gets written.
Temperature is in degrees Celsius, Voltage is in millivolts, and current is in Ampere.
Configuration options: [Auto] [0] - [65000]
Level 2 Threshold Value
Set the boundary separating the Level2 Action Value and Level3 Action Value. When
condition is below or equal to this value and above Level1 Threshold Value, then
Level2 Action Value gets written. If above, then Level3 Action Value gets written.
Temperature is in degrees Celsius, Voltage is in millivolts, and current is in Ampere.
Configuration options: [Auto] [0] - [65000]
Level 1 Action Value
Set the value for Action to take when condition lies below the first boundary. Power in
Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is in MHz.
Configuration options: [Auto] [0] - [65000]
Level 2 Action Value
Set the value for Action to take when condition lies between the first boundary and
second boundary. Power in Watt, Temperature in degrees Celsius, Current is in
Ampere, and BCLK is in MHz.
Configuration options: [Auto] [0] - [65000]
Level 3 Action Value
Set the value for Action to take when condition lies above the second boundary.
Power in Watt, Temperature in degrees Celsius, Current is in Ampere, and BCLK is
in MHz.
Configuration options: [Auto] [0] - [65000]
AI Features
Allows you to configure AI features.
Cooler Efficiency Customize
[Keep Training] Continuous evaluations will be performed on Cooler efficiency and
updated accordingly.
[Stop Training]
Cooler efficiency evaluations will stop and current evaluated
efficiency will be used.
[User Specify]
You can specify the Cooler efficiency manually and all predictions will
be based off this manual setting.