Beko HII64500FHT User Manual - Page 10
Danger
View all Beko HII64500FHT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 10 highlights
Our company shall not be liable for any damages that will arise due to using the product without a grounding Ainstallation in accordance with the local regulations. a DANGER: I The product must be connected to the mains . supply only by an authorised and qualified person. The product's warranty period starts only after correct installation. Manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons. "" DANGER: • The power cable must not be clamped, bent or trapped or come into contact with hot parts of the product. A damaged power cable must be replaced by a qualified electrician. Otherwise, there is risk of electric shock, short circuit or fire! • Connection must comply with national regulations. • The mains supply data must correspond to the data specified on the type label of the product. Type label is at the rear housing of the product. • Power cable of your product must comply with the values in "Technical specifications" table. As DANGER: •I BI•nesftoarlelatsiotanr,tidnigscaonnynwecotrkthoenptrhoeduecletcftrroicmalthe mains supply. There is the risk of electric shock! Connecting the power cable 1. This product must only be connected by a qualified electrician such as a technician from the local electricity company or NICEIC registered contractor to a suitable double-pole control unit with a minimum contact clearance of 3 mm in all poles. This control unit must be installed accordance with the IEE regulation. Failure to obey this instruction may cause operational problems and invalidate the product warranty. Additional protection by a residual current circuit breaker is recommended. If a cable is supplied with the product: II L1 L2 N 2N AC 380-415 V 1N AC 220-240 V 2. For single-phase connection, connect the wires as identified below: • Brown/Black cable = L (Phase) • Blue/Grey cable = N (Neutral) • Green/yellow cable = (E) = (Ground) 3. For double-phase connection, connect the wires as identified below: • Brown cable = L1 (Phase 1) • Black cable = L2 (Phase 2) • Blue/Grey cable = N (Neutral) • Green/yellow cable = (E) =I (Ground) » or • Black cable = L1 (Phase 1) • Grey cable = L2 (Phase 2) • Blue/Brown cable = N (Neutral) • Green/yellow cable = (E) 7.-7 (Ground) Installing the product If the oven is below: C C C C C 20 m C C E . E g in E C C C 1 0/EN