PRODUCT INSTALLATION Connecting your Equipment Plug the equipment into the output receptacles on the back panel of the unit. If your UPS is a 3U rack, there are a total of eight outlets, with seven outlets providing backup plus surge protection and one outlet for surge-only protection. However, if your UPS is a 2U rack, there are a total of six outlets, with five outlets providing backup plus surge protection and one outlet for surge-only protection. Please ensure that you do not exceed the maximum output rating (watts) of the UPS (refer to the UPS' back panel or the Technical Specifications section). Note: Connecting the RS232 computer interface port to a computer is necessary to run the software but is optional. Note: Connecting to the computer interface port is optional. The UPS works properly without a connection. Note: Connecting to the telephone/network surge protection connection is optional. The UPS works properly without a connection. CAUTION! Do not connect a laser printer to the battery backup receptacles on the UPS unless the UPS is rated 2000VA or greater. A laser printer draws significantly more power when printing than at idle, and may overload the UPS. CAUTION! RJ 45 Port Use only 26 AWG phone line. PRODUCT DIAGNOSTICS (2U Rack, 120VAC models shown) Protect RS232 Caution: Use only 26 AWG Phone Line Output SW1/SW2 Voltage OFF /OFF 110/220V OFF / ON 110/220V ON /OFF 120/230V ON / ON 127/240V Circuit Breaker Power Input UPS Output Surge Only (3U Rack, 120VAC models shown) (2U Rack, 230VAC models shown) Protect RS232 Caution: Use only 26 AWG Phone Line Output SW1/SW2Voltage OFF /OFF 110/215V OFF / ON 110/215V ON /OFF 120/225V ON / ON 127/235V Circuit Breaker Power Input UPS Output Surge Only (3U Rack, 230VAC models shown) Fig. 3: Rear Panel 1. The computer interface port is for the UPS monitoring and control. 2. The RJ45/RJ11 modular connectors are used for 10Base-T network/single-line telephone surge protection. 3. The output receptacles are NEMA 5-15R type. (IEC output sockets on 230VAC models) 4. The output circuit breakers will trip in the event the individual banks of the output receptacles exceed the rating of the circuit breaker. (Not on all models) 5. The input circuit breaker will trip in the event the load exceeds the UPS' power rating. 6. The input power cord has a NEMA 5-15P connector. (IEC input socket on 230VAC models) 7. The DIP switch setting may be changed by the user to set the desired inverter (on-battery) output voltage. 8. The "Surge Only" output receptacle is for surge protection only. It is not battery backed-up. 14 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17

PRODUCT DIAGNOSTICS
15
14
Connecting your Equipment
Plug the equipment into the output receptacles on the back panel of the unit. If
your UPS is a 3U rack, there are a total of eight outlets, with seven outlets
providing backup plus surge protection and one outlet for surge-only protection.
However, if your UPS is a 2U rack, there are a total of six outlets, with five
outlets providing backup plus surge protection and one outlet for surge-only
protection. Please ensure that you do not exceed the maximum output rating
(watts) of the UPS (refer to the UPS’ back panel or the Technical Specifications
section).
Note: Connecting the RS232 computer interface port to a computer is necessary to run the software but
is optional.
Note: Connecting to the computer interface port is optional. The UPS works properly without a
connection.
Note: Connecting to the telephone/network surge protection connection is optional. The UPS works
properly without a connection.
1.
The computer interface port is for the UPS monitoring and control.
2.
The RJ45/RJ11 modular connectors are used for 10Base-T
network/single-line telephone surge protection.
3.
The output receptacles are NEMA 5-15R type. (IEC output sockets on
230VAC models)
4.
The output circuit breakers will trip in the event the individual banks
of the output receptacles exceed the rating of the circuit breaker.
(Not on all models)
5.
The input circuit breaker will trip in the event the load exceeds the UPS’
power rating.
6.
The input power cord has a NEMA 5-15P connector. (IEC input socket on
230VAC models)
7.
The DIP switch setting may be changed by the user to set the desired
inverter (on-battery) output voltage.
8.
The “Surge Only” output receptacle is for surge protection only. It is not
battery backed-up.
PRODUCT INSTALLATION
CAUTION!
Do not connect a laser printer to the battery backup
receptacles on the UPS unless the UPS is rated 2000VA or
greater. A laser printer draws significantly more power when
printing than at idle, and may overload the UPS.
CAUTION!
RJ 45 Port Use only 26 AWG phone line.
Caution:
RS232
Circuit
Breaker
Power
Input
UPS Output
Surge Only
Protect
Use only
26 AWG
Phone Line
Caution:
RS232
Circuit
Breaker
Power
Input
UPS Output
Surge Only
(2U Rack, 120VAC models shown)
(2U Rack, 230VAC models shown)
Fig. 3: Rear Panel
(3U Rack, 120VAC models shown)
(3U Rack, 230VAC models shown)