Bosch HEI7052U Installation Instructions - Page 6

Verify that wiring to house is adequate, Verify that wiring inside house is adequate, Cabinet

Page 6 highlights

The electrical outlet must be located in the shaded space in Figure 3. Cabinet Requirements 7 1/2" (190.5 mm) 4 1/2" (114.3 mm) 3 1/2" (88.9 mm) 21" (533.4 mm) 30" (762 mm) 4 1/2" (114.3 mm) Figure 1: Cooktop Clearances Verify that wiring to house is adequate Contact your local utility company to verify that the present electric service to your home is adequate. In some instances, the size of the wiring to the house and service switch must be increased to handle the electrical load demanded by the range. Verify that wiring inside house is adequate Most wiring codes require a separate circuit with separate disconnect switch and fuses either in the main entrance panel or in a separate switch and fuse box. The range requires a minimum of a three wire 120/240 or 120/208 volt, 40 or 50 AMP, 60 Hz AC circuit. Check local codes for proper amperage ratings.A four wire connection is preferred. Most local building regulations and codes require that electrical wiring be done by licensed electricians. Be sure to install your range according to the electric codes in place in your region. This unit is designed for installation near adjacent walls and projecting surfaces constructed of combustible materials. English 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

English 4
The electrical outlet must be located in the shaded space in Figure 3.
Verify that wiring to house is adequate
Contact your local utility company to verify that the present electric service to your
home is adequate. In some instances, the size of the wiring to the house and ser-
vice switch must be increased to handle the electrical load demanded by the
range.
Verify that wiring inside house is adequate
Most wiring codes require a separate circuit with separate disconnect switch and
fuses either in the main entrance panel or in a separate switch and fuse box.
The range requires a minimum of a three wire 120/240 or 120/208 volt, 40 or 50
AMP, 60 Hz AC circuit. Check local codes for proper amperage ratings.A four wire
connection is preferred.
Most local building regulations and codes require that electrical wiring be done by
licensed electricians. Be sure to install your range according to the electric codes
in place in your region.
Cabinet Requirements
This unit is designed for installation near adjacent walls and projecting surfaces
constructed of combustible materials.
Figure 1:
Cooktop Clearances
21” (533.4 mm)
30”
(762 mm)
7 1/2”
(190.5 mm)
3 1/2”
(88.9 mm)
4 1/2”
(114.3 mm)
4 1/2”
(114.3 mm)