Bosch HES7132U Installation Instructions - Page 13

D Three Wire Flexible Conduit Con, nection, Completed Four Wire Flexible Conduit Connection,

Page 13 highlights

14. Properly secure flexible conduit at knockout on angle and at supply side junction box. The wiring is now complete. green ground screw black wire red wire white wire green ground wire Figure 14: Completed Four Wire Flexible Conduit Connection Note: DO NOT plug in range at this time. 5D) Three Wire Flexible Conduit Con- The Four Wire Connection is preferred, but where local codes and ordinances nection permit grounding through neutral and/or conversion to four wire is impractical, unit may be connected to the power supply via a three wire connection. 1. Disconnect electrical power at the breaker box. 2. Remove the terminal block cover to expose the terminal block. Figure 15: Terminal Block 3. Remove the top nut, star washer, and round washer from each post. Note: DO NOT remove last round washer, last nut or internal wire leads. 4. Place one terminal lug (packaged with this manual) on each post. Replace the star washer and round washer and secure with 20 inch pounds of torque. 5. Strip 3/8 (9.53 mm) inches of insulation from the end of each wire. 3/8 " Figure 16: Wire Stripping English 11

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

English 11
14.
Properly secure flexible conduit at knockout on angle and at supply side junc-
tion box. The wiring is now complete.
Note:
DO NOT plug in range at this time.
5D) Three Wire Flexible Conduit Con-
nection
The Four Wire Connection is preferred, but where local codes and ordinances
permit grounding through neutral and/or conversion to four wire is impractical, unit
may be connected to the power supply via a three wire connection.
1.
Disconnect electrical power at the breaker box.
2.
Remove the terminal block cover to expose the terminal block.
3.
Remove the top nut, star washer, and round washer from each post.
Note:
DO NOT remove last round washer, last nut or internal wire leads.
4.
Place one terminal lug (packaged with this manual) on each post. Replace the
star washer and round washer and secure with 20 inch pounds of torque.
5.
Strip 3/8 (9.53 mm) inches of insulation from the end of each wire.
Figure 14:
Completed Four Wire Flexible Conduit Connection
red wire
white wire
green
ground
screw
black wire
green ground wire
Figure 15:
Terminal Block
Figure 16:
Wire Stripping
3/8 “