The maximum permitted length for both rigid and flexible metal duct is shown in the table below. Number of Rigid Duct 90° Turns or Elbows Flexible Duct 0 66 ft. 45 ft. (2011 cm) (1372 cm) 1 56 ft. 36 ft. (1707 cm) (1097 cm) 2 48 ft. 29 ft. (1463 cm) (884 cm) 3 39 ft. 22 ft. (1189 cm) (671 cm) 4 30 ft. (914 cm) 16 ft. (488 cm) Note: Side and bottom exhaust installations have a 90° turn inside the dryer. To determine maximum exhaust length, add one 90° turn to the chart. More than two 90° turns are not recommended. For best performance, separate all turns by at least 4 ft. of straight duct, including distance between last turn and exhaust hood. Required parts The parts required for the exhaust air system (elbows, lines, exhaust air outlets) are not included in standard delivery of the dryer. Accessories The parts required for the exhaust air system can be obtained from customer service or your local dealer. Please follow the installation instructions supplied with kits. Side exhaust kit part no. WTZ 1265 Note: The maximum permitted number of 90° elbows (including this side exhaust kit) is four! i Special tool for cutting the hole in prepared side panel is required. Contact local dealer! Bottom exhaust kit part no. WTZ 1280 The parts required for the LP version can be obtained from your local dealer. Please follow the installation instructions supplied by the appropriate manufacturer! Note: Dryer must be checked for proper operation whenever the gas connections have been broken Left hinge kit part no. WTZ 1260 for all dryers except silver duo tone part no. WTZ 126S for duo tone silver dryers The door catch can be reversed if necessary. The door is hinged on the right at the factory. Pedestal Mounting Kit part no. WTZ 1295 (White Dryers) part. no. WTZ 1295P (Duo tone Silver) If mounting the dryer on the pedestal follow the instructions supplied with the pedestal. Exhaust vent hood The exhaust duct must end with an approved exhaust vent hood with swing out damper(s). DO NOT use an exhaust vent hood with magnetic latches. To avoid exhaust restriction, the outlet must be a minimum of 12 inches (30 cm) above ground level or any other obstructing surface. part no. WTZ 1270 Note: The maximum permitted number of 90° elbows (including this side exhaust kit) is four! LP - Gas Kit 9
![](/manual_guide/products/bosch-wtmc8520uc-installation-use-care-languages-9e7ee57/9.png)