Brother International HL-1660E Users Manual - English - Page 179
Card Full, Card W Error, Simm Error, Opt Io Error, Xx Size Error, Ignore Data, Install Simms Correctly
View all Brother International HL-1660E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 179 highlights
USER'S GUIDE Error Message 42 CARD FULL 43 CARD W ERROR 44 SIMM ERROR 45 MIO ERROR 46 OPT IO ERROR 47 CARD R ERROR XX SIZE ERROR IGNORE DATA (BR-Script 2 mode only) Meaning Card overflow Card write error Incorrect installation of SIMMs Error in communication with the MIO card Connection error with optional feeders and duplex unit. Card read error Paper of incorrect size is loaded into XX. XX is T2/ DX. Data is ignored because of an error in the PostScript® language program. Action Delete unnecessary macros or fonts, or use a new card. See page 4-32. Set the write protect switch of the card to OFF if it has been set to ON. Use a new card. If the same error occurs, consult your dealer or service personnel. Install SIMMs correctly, referring to the printed error message. See page 5-7. Install the MIO card correctly. See page 5-6. Check the interface cable connection between the printer and the fitted option. Use a new card. If the same error occurs, consult your dealer or service personnel. Set the correct size of paper in T2 or for duplex printing. See "Paper Handling" in Chapter 3. Press the RESET switch. If the same error occurs, you may need to add optional SIMM memory. See page 5-7. 7-4