Cisco WS-C3560E-48TD-E-RF Installation Guide - Page 95
Crossover and, Straight-Through Cable, Pinouts on, B-4, Table 3-2
UPC - 882658132629
View all Cisco WS-C3560E-48TD-E-RF manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 95 highlights
Chapter 3 Troubleshooting Diagnosing Problems Table 3-2 Common Problems and Their Solutions (continued) Symptom No connectivity. Unreadable characters on the management console. System LED is amber on the Catalyst 3508, 3512, or 3524 XL switch. Possible Cause Incorrect or bad cable. The following are indicated by no link at both ends: • A crossover cable was used when a straight-through was required, or vice-versa. • The cable is wired incorrectly. • STP checking for possible loops. Incorrect baud rate. Nonfatal or fatal POST error detected. Resolution • For the correct pinouts and the proper application of crossover vs. straight-through cables, see the "Crossover and Straight-Through Cable Pinouts" section on page B-4. • Replace with a tested good cable. • Wait 30 seconds for LED to turn green. Reset the emulation software to 9600 baud. Use the show POST command to see which POST test failed. 78-6456-04 Catalyst 3500 Series XL Hardware Installation Guide 3-5