Cisco WS-C3560X-48PF-S Hardware Installation Guide - Page 89
Power Specifications, Table A-3, Power Specifications for AC Power 12- - btu
![]() |
View all Cisco WS-C3560X-48PF-S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
Appendix A Technical Specifications Power Supply Module Specifications Table A-3 Power Specifications for AC Power 12-, 24-, and 48-Port Switches Power Specifications Maximum output power C3KX-PWR-1100WAC: 1100 W C3KX-PWR-715WAC: 715 W C3KX-PWR-350WAC: 350 W Input voltage range and frequency C3KX-PWR-1100WAC: 1100-W, 115 to 240 VAC (autoranging) 50 to 60 Hz C3KX-PWR-715WAC: 715 W, C3KX-PWR-350WAC: 350 W, 100 to 240 VAC (autoranging), 50 to 60 Hz Input current C3KX-PWR-1100WAC:12-6 A C3KX-PWR-715WAC: 10-5 A C3KX-PWR-350WAC: 4-2 A Output ratings Total input BTU1 Total output BTU1 C3KX-PWR-1100WAC: -56 [email protected] A C3KX-PWR-715WAC: -56 [email protected] A C3KX-PWR-350WAC: -56 [email protected] A C3KX-PWR-1100WAC: 4263 Btus per hour, 1250 W C3KX-PWR-715WAC: 2742 Btus per hour, 804 W C3KX-PWR-350WAC: 1357 Btus per hour, 398 W C3KX-PWR-1100WAC: 3751 Btus per hour, 1100 W C3KX-PWR-715WAC: 2438 Btus per hour, 765 W C3KX-PWR-350WAC: 1194 Btus per hour, 350 W 1. The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 100 VAC for the 350-W and 715-W power supplies and 115 VAC for the 1100-W power supply. Table A-4 Power Specifications for DC-Power 12-, 24-, and 48-Port Switches Power Specifications Maximum output power C3KX-PWR-440WDC: 440 W Input current C3KX-PWR-440WDC: 16 - 8 A DC input voltage C3KX-PWR-440WDC: -36 to -72 VDC Output ratings C3KX-PWR-440WDC: -56 [email protected] A Voltage range domestic C3KX-PWR-440WDC: -36 VDC (minimum) -48 VDC (nominal), -72 VDC (maximum) Voltage range international Total input BTU1 Total output BTU1 C3KX-PWR-440WDC: -36 VDC (minimum) -60 VDC (nominal), -72 VDC (maximum) C3KX-PWR-440WDC: 1841 Btus per hour, 540 W C3KX-PWR-440WDC: 1502 Btus per hour, 440 W Wire gauge for ground connection C3KX-PWR-440WDC: 12 AWG or 8 AWG Branch circuit protection C3KX-PWR-440WDC: 20 A 1. The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on -36 VDC. OL-19593-02 Catalyst 3750-X and 3560-X Switch Hardware Installation Guide A-3
![](/manual_guide/products/cisco-wsc3560x48pfl-hardware-installation-guide-0cefc4c/89.png)