Cisco WS-X45-SUP6-E Hardware Maintenance Manual - Page 106
If you are done with all SIMM replacement procedures, proceed to the Replacing Network
UPC - 882658167621
View all Cisco WS-X45-SUP6-E manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Memory Replacement Procedures Figure 5-9 Installing Main Memory SIMMs Top view Front of the chassis 1. Insert the SIMM into the socket at an angle 45° from vertical. 2. Push the SIMM down and back. 3. The socket guide posts insert through the SIMM holes (on both sides). 4. The locking spring will clip the back of the SIMM when it is fully installed (on both sides). Polarization notch Side view 1. Insert the SIMM into the socket at an angle 45° from vertical. 3. The socket guide posts insert through the SIMM holes (on both sides). 4. The locking spring will clip the back of the SIMM when it is fully installed (on both sides). 2. Push the SIMM down and back. H1152 Caution You will feel some resistance, but do not use excessive force on the SIMM and do not touch the surface components to avoid damaging them. Step 6 Repeat Steps 2 through 5 for each main memory SIMM. If you are done with all SIMM replacement procedures, proceed to the section "Replacing Network Processor Modules" later in this chapter. 5-12 Cisco 4000 Series Hardware Installation and Maintenance