Table B-3, Memory Test Error Codes, Error Code, Description, Recommended Action
View all Compaq ProLiant 1850R manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 169 highlights
Test Error Codes Table B-3: Memory Test Error Codes continued Error Code Description Recommended Action 203-XX Memory write/read test failed The following steps apply to error codes 203-XX through 206-XX: 204-XX 205-XX 206-XX Memory address test failed Walking I/O test failed Increment pattern test failed 1. Replace the memory module and retest. 2. Replace the processor and retest. 3. Replace the memory expansion board and retest. 207-XX Invalid memory configuration; check DIMM installation. DIMMs installed have 8K refresh Replace memory modules. 208-XX Invalid memory detected; check DIMM installation Be sure that the memory is installed. Then, refer to your server-specific user documentation for supported memory and replace memory modules as indicated. 210-XX Random pattern test failed 1. Replace the memory module and retest. 2. Replace the processor and retest. 3. Replace the memory expansion board and retest. 0211-01 0211-02 RAND test failed Error while saving test block The following steps apply to error codes 0211-01 through 0214-89: 1. Replace the memory module/board and retest. 0211-03 0211-04 Error while restoring test block Insufficient memory to perform test 2. Replace the system board and retest. 3. Replace the memory expansion board and retest 0211-05 Failed inverted pattern compare, but RAM was correct 0212-01 RAM long test failed 0212-02 Error while saving test block continued B-4 HP Servers Troubleshooting Guide