Compaq ProLiant 8500 Compaq Parallel Database Cluster Model PDC/O2000 for Orac - Page 52
Cabling the Storage Hubs or Switches to the RA4000 Array Controllers
View all Compaq ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
2-28 Compaq Parallel Database Cluster Model PDC/O2000 for Oracle8i and Windows 2000 Administrator Guide I The even-numbered Fibre Channel SAN Switch (Fibre Channel SAN Switch #2) is connected to the active array controller in each even-numbered RA4000/RA4100 Array (2 and 4). I The even-numbered Fibre Channel SAN Switch is connected to the standby array controller in each odd-numbered RA4000/RA4100 Array (1, 3, and 5). NOTE: The following active/active configurations are examples only. You are not required to follow these configurations. For more information about installing active/active configurations, refer to these sections in Chapter 5, "Installation and Configuration": I Cabling the Fibre Host Adapters to the Storage Hubs or Switches I Cabling the Storage Hubs or Switches to the RA4000 Array Controllers In Figures 2-11 through 2-14, active I/O path components have been shaded to distinguish them from standby (inactive) components. Black Fibre Channel cables identify connections between active components; gray cables identify connections between standby components.