Compaq ProSignia 500 SMART-2DH Array Controller Reference Guide - Page 181
SMART-2DH Array, Controller Installation Guide, Slot x Drive Array - ProLiant Drive Storage
View all Compaq ProSignia 500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 181 highlights
H-6 POST Error Messages POST Error Messages continued 1777 Slot x Drive Array - ProLiant Drive Storage System Problem Detected (followed by one or more of the following): SCSI Port (y): Cooling Fan Malfunction Detected SCSI Port (y): Overheated Condition Detected SCSI Port (y): Side-Panel must be Closed to Prevent Overheating SCSI Port (y): Redundant Power Supply Malfunction Detected SCSI Port (y): Wide SCSI Transfer Failed SCSI Port (y): Interrupt Signal Inoperative (RESUME = F1 KEY) Check cooling fan operation by placing hand over fan. Check internal plenum cooling fan in tower servers or storage systems. If fan is not operating, check for obstructions and check all internal connectors. Replace unit side panel if removed. If the ProLiant Storage System power LED is amber instead of green, this indicates a redundant power supply failure. Check SCSI cables. Note that port 1 refers to the "internal" SCSI bus, and port 2 refers to the "external" SCSI bus. If the message indicates to check SCSI cables, verify your cabling using the diagrams in the SMART-2DH Array Controller Installation Guide. If the routing is correct, replace cables on the specified port until the POST message is eliminated. 1778 Slot x Drive Array resuming Automatic Data Recovery process. No action required. This message appears when a controller resets or power cycle occurs while Automatic Data Recovery is in progress. 1779 Slot x Drive Array - Replacement drive(s) detected OR previously failed drive(s) now appear to be operational: Port (y): SCSI ID (x): Restore data from backup if replacement drive x has been installed. If this message appears and drive x (identified by its SCSI ID) has not been replaced, this indicates an intermittent drive failure. This message also appears once immediately following drive replacement before data is restored from backup. 1783 Slot x Drive Array Controller Failure. If this message appears immediately following a ROM installation, the ROM is defective or not installed properly. Check that the controller is firmly inserted in its slot. Try upgrading the System ROMs. Otherwise, replace the SMART2DH Controller. 1784 Slot x Drive Array Drive Failure. The following SCSI drive(s) should be replaced: SCSI Port (y) SCSI ID (x) Check for loose cables. Replace defective drive x and/or cable(s). Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: O-APPH.DOC Last Saved On: 2/27/98 12:10 PM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED