Compaq ProSignia 500 SMART-2DH Array Controller Reference Guide - Page 27
Restoring an Array to Its Original, Controller, and Array B with drive IDs 4
View all Compaq ProSignia 500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
2-9 Restoring an Array to Its Original Controller If you have moved an array from one controller to another, you can restore it to its original controller. Figures 2-4 through 2-6 show the consecutive configurations required to restore an array to its original controller (or to a replaced controller in the event of controller failure). Figure 2-4 shows the consolidated configuration that includes Array A with drive IDs 0 through 3 and Array B with drive IDs 4, 5, and 6. Moving Array B back to Controller 2 creates an interim four-array state, with Array B on Controller 1 and Array A on Controller 2 appearing as failed. Running Array Configuration Utility removes the "failed" arrays and restores the original two-array configuration. Controller 1 Controller 2 ID6 z ID6 ID5 y Array B ID5 ID4 x ID4 ID3 d ID3 ID2 c ID2 ID1 b Array A ID1 ID0 a ID0 Figure 2-4. Arrays A and B both attached to Controller 1 Controller 1 ID6 Controller 2 ID6 z ID5 Array A ID5 y Array B ID4 "Failed ID4 x " ID3 d ID3 ID2 c ID2 ID1 b Array A ID1 Array A ID0 a ID0 "Failed" SMART-2DH Array Controller Reference Guide Writer: Pamela King Project: SMART-2DH Array Controller Reference Guide Comments: 295469-002 File Name: C-CH02.DOC Last Saved On: 2/27/98 11:25 AM COMPAQ CONFIDENTIAL - NEED TO KNOW REQUIRED