D-Link DES-5024 Product Manual - Page 39

Local Console Management

Page 39 highlights

Fast Ethernet Switching System User's Guide Local Console Management Local Console Management is always done through the RS-232 serial port and requires a direct connection between the DES-5024 and a PC. This type of management is very useful when the network is down and the DES-5024 cannot be reached by any other means. Use Local Console Management to log into the DES-5024 for the first time. You do not need to know the IP address to log into the DES-5024 using Local Console Management. You can change all the settings and configure the DES-5024, set the IP address and perform other management functions. The management session will timeout after five minutes if you have not taken any action. Press enter a few times to refresh the screen. You will have to log in again after a timeout. Follow these steps to begin a management session using Local Console Management: 1. Attach the male end of the RS-232 serial cable provided with the DES-5024 to the RS-232 port located at the front of the DES-5024. 2. Attach the other end to the serial port of a PC or workstation. 3. Run a terminal emulation program using the following settings: • Emulation: VT-100/ANSI compatible • BPS: 19 200 • Data bits: 8 • Parity: None • Stop bits: 1 • Flow Control: None • Enable: Terminal keys 4. Press Enter to display the login panel. 5. Log in using the default User Name and Password. The User Name and Password are case sensitive. • User Name: D-Link • Default Password: D-Link 5. Press Enter to reach the Main menu. Managing the DES-5024 31

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93

Fast Ethernet Switching System User’s Guide
Managing the DES-5024
31
Local Console Management
Local Console Management is always done through the RS-232 serial port and requires a
direct connection between the DES-5024 and a PC. This type of management is very
useful when the network is down and the DES-5024 cannot be reached by any other
means.
Use Local Console Management to log into the DES-5024 for the first time. You do not
need to know the IP address to log into the DES-5024 using Local Console Management.
You can change all the settings and configure the DES-5024, set the IP address and
perform other management functions. The management session will timeout after five
minutes if you have not taken any action. Press enter a few times to refresh the screen.
You will have to log in again after a timeout.
Follow these steps to begin a management session using Local Console Management:
1.
Attach the male end of the RS-232 serial cable provided with the DES-5024 to the
RS-232 port located at the front of the DES-5024.
2.
Attach the other end to the serial port of a PC or workstation.
3.
Run a terminal emulation program using the following settings:
Emulation:
VT-100/ANSI compatible
BPS:
19 200
Data bits:
8
Parity:
None
Stop bits:
1
Flow Control:
None
Enable:
Terminal keys
4.
Press Enter to display the login panel.
5.
Log in using the default User Name and Password. The User Name and Password are
case sensitive.
User Name:
D-Link
Default Password:
D-Link
5.