D-Link DIS-300G-14PSW Quick Installation Guide - Page 5

Alarm Relay and Ground, DIS-300G-8PSW/DIS-300G-14PSW

Page 5 highlights

DIS-300G-8PSW/DIS-300G-14PSW Quick Installation Guide Alarm Relay and Ground The alarm relay output contacts are in the middle of the DC terminal block connector as shown in the figure below. The alarm relay out is "Normal Open", and it will be closed when detected any predefined failure such as power failures or Ethernet link failures. The relay output with current carrying capacity of 0.5A @ 24 VDC 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

Quick Installation Guide
5
DIS-300G-8PSW/DIS-300G-14PSW
Alarm Relay and Ground
The alarm relay output contacts are in the middle of the DC terminal block connector as shown in
the figure below.
The alarm relay out is “Normal Open”, and it will be closed when detected any predefined failure
such as power failures or Ethernet link failures.
The relay output with current carrying capacity of 0.5A @ 24 VDC