4 HOOD EXHAUST DUCT When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal; absolutely do not use plastic duct. Check that all connections are made securely. Please read the following carefully: Exhaust connection: The hood exhaust has been designed to connect to a standard 3-1/4" x 10" rectangular duct. If round duct is required, a rectangular-to-round adapter must be used. Rear exhaust: If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the space between the studs, or wall should be prepared at the time it is constructed by leaving enough space between wall studs to accommodate exhaust. Maximum duct length: For satisfactory air movement, the total duct length of 3-1/4" X 10" rectangular or 6" diameter round duct should not exceed 140 feet. Elbows, adapters, wall, roof caps, etc. present additional resistance to air flow and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total length, add the equivalent lengths of all transitions and adapters plus the length of all straight duct sections. Figure 4 shows the approximate feet of equivalent length of some typical ductwork parts. Use the values in parentheses for calculating air flow resistance equivalent, which should total less than 140 feet. Figure 4 5 TOOLS RECOMMENDED FOR INSTALLATION • Phillips Screwdriver • Electric Drill • 1/2", 5/8" and 3/32" Drill Bits • 1-1/2" Wood Bit or Metal Hole Cutter (if metal cabinet is used) • Saw to cut exhaust opening (if needed) • Protective Drop Cloth for product and range -you may also use carton for protection • Tape • Scissors • Pencil • Measure 6 INSTALLATION HARDWARE The INSTALLATION HARDWARE items 1-7 are in a small bag. Items 8 and 9 are packed separately. All items are in a small carton packed below the oven. ITEM 1 2 3 4 5 6 7 8 9 NAME QUANTITY Wood Screw 5 X 30 mm 6 Toggle Bolt #10 - 24 X 50 mm 4 Top Cabinet Screw 5 X 60 mm 2 Flat Washer 5 mm diameter 2 Cord Holder 1 Grommet 1 Tapping Screw 4 x 12 mm 1 Exhaust Damper Assembly 1 Charcoal Filter 1 PART CODE XTSSD50P35000 LX-BZ0195WRE0 XBRSD50P60000 XWHSD50-16300 LX-MZB001MRE0 LBSHC0040MRE0 XOTSD40P12000 FFTA-B003MRK0 / FFTA-B005MRK0 PFIL-B004MRE0 Figure 5 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

3
4
HOOD EXHAUST DUCT
When the hood is vented to the outside, a hood exhaust duct is required. All ductwork must be metal;
absolutely do not use plastic duct. Check that all connections are made securely. Please read the following
carefully:
Exhaust connection: The hood exhaust has been designed to connect to a standard 3-1/4” x 10” rectangular
duct. If round duct is required, a rectangular-to-round adapter must be used.
Rear exhaust:
If a rear or horizontal exhaust is to be used, care should be taken to align the exhaust with the
space between the studs, or wall should be prepared at the time it is constructed by leaving enough space
between wall studs to accommodate exhaust.
Maximum duct length: For satisfactory air movement, the total duct length of 3-1/4” X 10” rectangular or 6”
diameter round duct should not exceed 140 feet.
Elbows, adapters, wall, roof caps, etc. present addi-
tional resistance to air flow and are equivalent to
a section of straight duct which is longer than their
actual physical size. When calculating the total
length, add the equivalent lengths of all transitions
and adapters plus the length of all straight duct
sections. Figure 4 shows the approximate feet of
equivalent length of some typical ductwork parts.
Use the values in parentheses for calculating air
flow resistance equivalent, which should total less
than 140 feet.
5
TOOLS RECOMMENDED FOR INSTALLATION
• Phillips Screwdriver
• Electric Drill
• 1/2”, 5/8” and 3/32” Drill Bits
• 1-1/2” Wood Bit or Metal Hole Cutter (if metal cabinet is used)
• Saw to cut exhaust opening (if needed)
• Protective Drop Cloth for product and range -you may also use carton for protection
• Tape
• Scissors
• Pencil
• Measure
6
INSTALLATION HARDWARE
The INSTALLATION HARDWARE items
1
-
7
are in a small bag. Items
8
and
9
are packed separately. All
items are in a small carton packed below the oven.
ITEM
NAME
QUANTITY
PART CODE
1
Wood Screw 5 X 30 mm
6
XTSSD50P35000
2
Toggle Bolt #10 - 24 X 50 mm
4
LX-BZ0195WRE0
3
Top Cabinet Screw 5 X 60 mm
2
XBRSD50P60000
4
Flat Washer 5 mm diameter
2
XWHSD50-16300
5
Cord Holder
1
LX-MZB001MRE0
6
Grommet
1
LBSHC0040MRE0
7
Tapping Screw 4 x 12 mm
1
XOTSD40P12000
8
Exhaust Damper Assembly
1
FFTA-B003MRK0 / FFTA-B005MRK0
9
Charcoal Filter
1
PFIL-B004MRE0
Figure 4