Dacor DMO24 Installation Instruction - Over the Range Microwave Oven/Hood Syst - Page 4

Ventilation System, Preparation Of The Oven

Page 4 highlights

7 PREPARATION OF THE OVEN 1. Open the bottom of the carton, bend the carton flaps back and tilt the oven over to rest on plastic foam pad. Lift carton off oven and remove all packing materials, Installation Instructions, Wall Template, Top Template, Charcoal Filter, Turntable and Turntable Support; however, DO NOT REMOVE THE WAVEGUIDE COVER, which is located on the ceiling in the oven cavity. SAVE THE CARTON AS IT MAY MAKE INSTALLATION EASIER. 2. CHECK THE OVEN. Check the oven for any damage, such as misaligned or bent door, damaged door seals and sealing surfaces, broken or loose door hinges and latches and dents inside the cavity or on the door. If there is any damage, do not operate the oven and contact your dealer or DACOR AUTHORIZED SERVICER. 8 VENTILATION SYSTEM This Microwave Oven/Hood is designed for adaptation to three types of hood ventilation systems. Select the type required for your installation. A. Recirculating - non-vented, ductless. Follow installation procedure A. Recirculating requires the use of the Charcoal Filter 9 (previously installed or is packed in the packing foam). B. Horizontal Exhaust - outside ventilation. Follow installation procedure B. C. Vertical Exhaust - outside ventilation. Follow installation procedure C. (A) RECIRCULATING: Non-Vented, Ductless Operation The unit is shipped assembled for recirculating. Attach the Charcoal Filter to the upper side of the oven by sliding into the tabs. See Figure 6. NOTE: 1. The Exhaust Damper Assembly 8 is not required for recirculating operation. 2. The Charcoal Filter should be replaced every 6 to 12 months, depending on use. 9 Tabs Tabs Figure 6 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8

8
VENTILATION SYSTEM
This Microwave Oven/Hood is designed for adaptation to three types of hood ventilation systems. Select the
type required for your installation.
A. Recirculating — non-vented, ductless. Follow installation procedure A. Recirculating requires the use of
the Charcoal Filter
9
(previously installed or is packed in the packing foam).
B. Horizontal Exhaust — outside ventilation. Follow installation procedure B.
C. Vertical Exhaust — outside ventilation. Follow installation procedure C.
(A) RECIRCULATING: Non-Vented, Ductless Operation
The unit is shipped assembled for recirculating. Attach the Charcoal Filter to the upper side of the oven by
sliding into the tabs. See Figure 6.
NOTE:
1. The Exhaust Damper Assembly
8
is not required for
recirculating operation.
2. The Charcoal Filter should be replaced every 6 to 12 months, depending on use.
7 PREPARATION OF THE OVEN
1. Open the bottom of the carton, bend the carton flaps back and tilt the oven over to rest on plastic foam pad.
Lift carton off oven and remove all packing materials, Installation Instructions, Wall Template, Top Template,
Charcoal Filter, Turntable and Turntable Support; however, DO NOTREMOVE THE WAVEGUIDE
COVER, which is located on the ceiling in the oven cavity. SAVE THE CARTON AS IT MAY MAKE
INSTALLATION EASIER.
2. CHECK THE OVEN.
Check the oven for any damage, such as misaligned or bent door, damaged door seals and sealing
surfaces, broken or loose door hinges and latches and dents inside the cavity or on the door. If there is
any damage, do not operate the oven and contact your dealer or DACOR AUTHORIZED SERVICER.
4
Figure 6
Tabs
Tabs
9