Dacor DTHP48 Installation Instruciton - Distinctive Wall Mount Range Hood - Page 23

WARNING, Grounding by External Cold Water Pipe, Inserting Light Bulbs with the Suction Cup Tool

Page 23 highlights

Installation Instructions WARNING • Do not ground the circuit to a gas line. • Do not ground the circuit to a hot water pipe. • Water lines that are insulated must be jumped to assure continuity to ground. See below. To house circuit breaker panel or fuse box Separate No. 10 (minimum) copper ground wire Wire nut, 3 places Fasten clamp tightly on metal pipe No. 4 copper wire Meter UL/CSA approved NEMA strain relief Junction box Clamps Bare metal To Range Hood Insulated Pipe Jumper (if necessary) Grounding by External Cold Water Pipe Inserting Light Bulbs 3 Make sure dimmable bulbs are used. The electronic board was designed for dimmable lights and using non-dimmable types will cause damage and faulty performance. Shut the main circuit breaker OFF while inserting new or while changing bulbs. If an electrical short occurs while the main power circuit is ON, significant damage can occur. Follow the diagram to the right for instructions. 1. Attach the suction cup to the lens of a dimmable light bulb. (Both are supplied parts.) 2 Make sure the bulb faces are clean so the suction cup can stick. 2. Insert the bulb into one of the light fixtures. 3. Screw it into place and remove the suction cup. 1 4. Repeat for the remaining light fixtures. 5. Switch the main circuit power ON. Inserting Light Bulbs with the Suction Cup Tool Replacement Part Number 700975 Replacement Part Description Halogen Bulb Replacement Kit (1 bulb + 1 suction cup tool) 21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31

21
Installation Instructions
WARNING
Do not ground the circuit to a gas line.
Do not ground the circuit to a hot water pipe.
Water lines that are insulated must be jumped to assure continuity to ground. See below.
Inserting Light Bulbs
Make sure dimmable bulbs are used. The electronic board
was designed for dimmable lights and using non-dimmable
types will cause damage and faulty performance.
Shut the main circuit breaker OFF while inserting new or
while changing bulbs.
If an electrical short occurs while the
main power circuit is ON, significant damage can occur.
Follow the diagram to the right for instructions.
1.
Attach the suction cup to the lens of a dimmable light
bulb. (Both are supplied parts.)
Make sure the bulb faces are clean so the suction cup
can stick.
2.
Insert the bulb into one of the light fixtures.
3.
Screw it into place and remove the suction cup.
4.
Repeat for the remaining light fixtures.
5.
Switch the main circuit power ON.
Insulated Pipe Jumper
(if necessary)
Grounding by External Cold Water Pipe
UL/CSA approved
NEMA strain relief
Fasten clamp tightly
on metal pipe
Separate No. 10 (minimum)
copper ground wire
To house circuit breaker
panel or fuse box
To Range Hood
Wire nut,
3 places
Junction box
Meter
Clamps
Bare metal
No. 4 copper
wire
Inserting Light Bulbs with the Suction Cup Tool
3
2
1
Replacement Part Number
Replacement Part Description
700975
Halogen Bulb Replacement Kit (1 bulb + 1 suction cup tool)