Dacor RV30 Installation Instructions - Page 15
Wiring Diagram B - Raised Vent Electrical Connections
View all Dacor RV30 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
Installation Instructions Raised vent electrical connections see Wiring Diagram B Cabinet blower (CABP3) Junction box Connect wires/conduit according to remote or in-line blower installation instructions REMP series blower shown Blower electrical connections - see Wiring Diagram A Power supply wiring from junction to raised vent Power supply wiring from raised vent to CABP3 blower Electrical Wiring - Cabinet Blower Installations (CABP3) Raised vent electrical connections see Wiring Diagram B Junction box CABP3 electrical panel L2 N2 GND Black = L2 White = N2 Green - Gnd Wiring to Blower Output terminals on raised vent Wiring Diagram A - Electrical Connections for CABP3 Blower Floor Power supply wiring from raised vent to remote or in-line blower Electrical wiring from raised vent to junction box Electrical Wiring - Remote or In-line Blower Installations (ILHSF or REMP series) Raised vent electrical terminals Blower power from Blower Output terminals on raised vent to blower (all types) Black = L2 White = N2 Green - Gnd Ground Power Input Blower Output Raised vent electrical panel Junction box GREEN To circuit breaker panel or fuse box WHITE Wire nut, 3 places BLACK Connect wires to Power Input terminals on raised vent To blower Black = L1 White = N1 Green - Gnd Wiring Diagram B - Raised Vent Electrical Connections 13