Danby DPAC10011 Product Manual - Page 8

&gt

Page 8 highlights

7 OPERATION (cont'd) DEHUMIDIFIER Note: Dining dehunddifier mode, the exhaust hose does not have to be vented outdoors. 1) Press the ON/OFF key pad to switch the unit on (Fig. G) 2) Press the MODE key (Fig. H) until the DRY indicator illuminates on the control panel (Fig.I).Each press of the MODE key will advance to a different mode setting (Cool-Dehumidifier-Fan). IMPORTANT: There is no temperature adjustment during dehumidifier mode. If the room temperature is greater than 77°F (25°C), the fan speed can be adjusted, otherwise the fan speed is fixed at LOW speed. Fig. G 8104 IMPORTANT: The drain hose must be installedduring dehumidifier mode. I_ I The function of continuous drain can be performed using the following steps: 1) To save having to periodically empty the water tank, this unit can be configured for continuous drain. You can use the supplied drain hose to connect to the continuous drain connector. 2) Unscrew and remove the drain cover at the rear of the unit (Fig.5). Back of the unit 3) Remove the soft rubber stopper, and place it in the water tank for safe keeping (Fig.6). 4) Insert the drain hose through the hole of the drain cover (Fig. 7). DES COV • Ifs! 5) Ensure the rubber seal ring is properly seated in the end of the hose as shown in Fig. 7. 6) Connect the drain hose to the drain port (Fig. 8). r Ng. 6 I 7) Tighten the drain cover in clockwise direction onto the rear of the unit (Fig. 8). INSTALLING PVC DRAIN HOSE When using the continuous drain function, the PVC hose must be placed horizontally below the drainage hole. Avoid uneven ground and folding the hose NOTE: Should you damage or misplace the pvc drain hose, a standard garden hose can be used. Soil tubber stopper Drain 'ova N FIR. • I Dialll covet Drain hove X/ • }12. 8 Drain covet Drainlion ? t. , ci . 1 rft;4ref 47>

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24

7
OPERATION
(cont'd)
DEHUMIDIFIER
Note:
Dining
dehunddifier
mode,
the
exhaust
hose
does
not
have
to
be
vented
outdoors.
1)
Press
the
ON/OFF
key
pad
to
switch
the
unit
on
(Fig.
G)
2)
Press
the
MODE
key
(Fig.
H)
until
the
DRY
indicator
illuminates
on
the
control
panel (Fig.I).Each
press
of
the
MODE
key
will
advance
to
a
different
mode
setting
(Cool
-Dehumidifier
-Fan).
IMPORTANT:
There
is
no
temperature
adjustment
during
dehumidifier
mode.
If
the
room
temperature
is
greater
than
77°F
(25°C),
the
fan
speed
can
be
adjusted,
otherwise
the
fan
speed
is
fixed
at
LOW
speed.
IMPORTANT:
The
drain
hose
must
be
installedduring
dehumidifier
mode.
The
function
of
continuous
drain
can
be
performed
using
the
following
steps:
1)
To
save
having
to
periodically
empty
the
water
tank,
this
unit
can
be
configured
for
continuous
drain.
You
can
use
the
supplied
drain
hose
to
connect
to
the
continuous
drain
connector.
2)
Unscrew
and
remove
the
drain
cover
at
the
rear
of
the
unit
(Fig.5).
Fig.
G
8104
I_
I
3)
Remove
the
soft
rubber
stopper,
and
place
it
in
the
water
tank
for
safe
DES
COV
keeping
(Fig.6).
4)
Insert
the
drain
hose
through
the
hole
of
the
drain
cover
(Fig.
7).
5)
Ensure
the
rubber
seal
ring
is
properly
seated
in
the
end
of
the
hose
as
shown
in
Fig.
7.
6)
Connect
the
drain
hose
to
the
drain
port
(Fig.
8).
7)
Tighten
the
drain
cover
in
clockwise
direction
onto
the
rear
of
the
unit
(Fig.
8).
INSTALLING
PVC
DRAIN
HOSE
When
using
the
continuous
drain
function,
the
PVC
hose
must
be
placed
horizontally
below
the
drainage
hole.
Avoid
uneven
ground
and
folding
the
hose
NOTE:
Should
you
damage
or
misplace
the
pvc
drain
hose,
a
standard
garden
hose
can
be
used.
X/
Back
of
the
unit
Ifs!
r
Ng.
6
I
Soil
tubber
stopper
Drain
'ova
N
FIR.
I
Dialll
covet
Drain
hove
}12.
8
?
t .
Drain
covet
,
ci
.
;ref
Drain
li
on
1
rft4
47>