Dell Brocade 5100 Brocade Fabric OS v7.3.0a Release Notes v2.0 - Page 53
Fabric OS v7.3.0a Release Notes v2.0, of 55
View all Dell Brocade 5100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 53 highlights
Closed with Code Change Defects in Fabric OS v7.3.0a Defect ID: DEFECT000515787 Technical Severity: Medium Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.3.0 Technology Area: FCIP Symptom: The CLI command 'portshow fciptunnel --reset' does not reset the connected count field properly in the FCIP tunnel statistics, and so it may show an invalid count after this command is issued. Condition: Issue may occur when the 'portshow fciptunnel --reset' command is issued to reset the FCIP tunnel counters. Workaround: Avoid using the '--reset' option with the portshow fciptunnel command. Defect ID: DEFECT000516255 Technical Severity: High Probability: Low Product: FOS Technology: Distance Reported In Release: FOS7.3.0 Technology Area: FCIP Symptom: Any replication devices using ELS (PRLI) and ELS _ACC frames as heartbeat during the replication might have potential traffic disrupted when doing non-disruptive firmwaredownload in FCR configuration. Condition: When replication devices on the edge fabric to 7840 through EX port. Replication devices must use ELS (PRLI) and ELS_ACC as heart beat for every few seconds. The windows for heartbeat loss is 3 minutes. IO will stop if replication device can not recover. Defect ID: DEFECT000516599 Technical Severity: High Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.2.0 Technology Area: FCIP Symptom: XTUN-1008 messages reported every 5 minutes in the RAS log and BNA console Condition: After extended uptime in a large FCIP FCP Fast Write and Open Systems Tape Pipelining configuration. Recovery: Reboot FCIP switch or power cycle the slot that is reporting the messages Defect ID: DEFECT000516703 Technical Severity: High Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.1.0 Technology Area: FCIP Symptom: FICN-1062 and FICN-1063 abort messages on XRC and IFCC on host. Condition: In a large FICON disk mirroring configuration that includes base and alias devices in the connected primary controllers Workaround: None required - IFCCs will occur and normal channel error recovery will complete Defect ID: DEFECT000516934 Technical Severity: High Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Equipment Status Symptom: FC16-64 DC power consumption is set to 160W but needs to be lowered to its actual maximum. Condition: FC16-64 is inserted in a 8510-8 or 8510-4 chassis, slotshow -p will display DC power consumption as 160W. Fabric OS v7.3.0a Release Notes v2.0 Page 53 of 55