Closed with Code Change Defects in Fabric OS v7.3.0a Defect ID: DEFECT000515787 Technical Severity: Medium Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.3.0 Technology Area: FCIP Symptom: The CLI command 'portshow fciptunnel --reset' does not reset the connected count field properly in the FCIP tunnel statistics, and so it may show an invalid count after this command is issued. Condition: Issue may occur when the 'portshow fciptunnel --reset' command is issued to reset the FCIP tunnel counters. Workaround: Avoid using the '--reset' option with the portshow fciptunnel command. Defect ID: DEFECT000516255 Technical Severity: High Probability: Low Product: FOS Technology: Distance Reported In Release: FOS7.3.0 Technology Area: FCIP Symptom: Any replication devices using ELS (PRLI) and ELS _ACC frames as heartbeat during the replication might have potential traffic disrupted when doing non-disruptive firmwaredownload in FCR configuration. Condition: When replication devices on the edge fabric to 7840 through EX port. Replication devices must use ELS (PRLI) and ELS_ACC as heart beat for every few seconds. The windows for heartbeat loss is 3 minutes. IO will stop if replication device can not recover. Defect ID: DEFECT000516599 Technical Severity: High Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.2.0 Technology Area: FCIP Symptom: XTUN-1008 messages reported every 5 minutes in the RAS log and BNA console Condition: After extended uptime in a large FCIP FCP Fast Write and Open Systems Tape Pipelining configuration. Recovery: Reboot FCIP switch or power cycle the slot that is reporting the messages Defect ID: DEFECT000516703 Technical Severity: High Probability: Medium Product: FOS Technology: Distance Reported In Release: FOS7.1.0 Technology Area: FCIP Symptom: FICN-1062 and FICN-1063 abort messages on XRC and IFCC on host. Condition: In a large FICON disk mirroring configuration that includes base and alias devices in the connected primary controllers Workaround: None required - IFCCs will occur and normal channel error recovery will complete Defect ID: DEFECT000516934 Technical Severity: High Probability: Medium Product: FOS Technology: Monitoring/RAS Reported In Release: FOS7.3.0 Technology Area: Equipment Status Symptom: FC16-64 DC power consumption is set to 160W but needs to be lowered to its actual maximum. Condition: FC16-64 is inserted in a 8510-8 or 8510-4 chassis, slotshow -p will display DC power consumption as 160W. Fabric OS v7.3.0a Release Notes v2.0 Page 53 of 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

Closed with Code Change Defects in Fabric OS v7.3.0a
Fabric OS v7.3.0a Release Notes v2.0
Page 53 of 55
Defect ID:
DEFECT000515787
Technical Severity:
Medium
Probability:
Medium
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.3.0
Technology Area:
FCIP
Symptom:
The CLI command 'portshow fciptunnel --reset' does not reset the connected count field properly in
the FCIP tunnel statistics, and so it may show an invalid count after this command is issued.
Condition:
Issue may occur when the 'portshow fciptunnel --reset' command is issued to reset the FCIP tunnel
counters.
Workaround:
Avoid using the '--reset' option with the portshow fciptunnel command.
Defect ID:
DEFECT000516255
Technical Severity:
High
Probability:
Low
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.3.0
Technology Area:
FCIP
Symptom:
Any replication devices using ELS (PRLI) and ELS _ACC frames as heartbeat during the replication
might have potential traffic disrupted when doing non-disruptive firmwaredownload in FCR
configuration.
Condition:
When replication devices on the edge fabric to 7840 through EX port.
Replication devices must use ELS (PRLI) and ELS_ACC as heart beat for every few seconds.
The
windows for heartbeat loss is 3 minutes. IO will stop if replication device can not recover.
Defect ID:
DEFECT000516599
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.2.0
Technology Area:
FCIP
Symptom:
XTUN-1008 messages reported every 5 minutes in the RAS log and BNA console
Condition:
After extended uptime in a large FCIP FCP Fast Write and Open Systems Tape Pipelining
configuration.
Recovery:
Reboot FCIP switch or power cycle the slot that is reporting the messages
Defect ID:
DEFECT000516703
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Distance
Reported In Release:
FOS7.1.0
Technology Area:
FCIP
Symptom:
FICN-1062 and FICN-1063 abort messages on XRC and IFCC on host.
Condition:
In a large FICON disk mirroring configuration that includes base and alias devices in the connected
primary controllers
Workaround:
None required
IFCCs will occur and normal channel error recovery will complete
Defect ID:
DEFECT000516934
Technical Severity:
High
Probability:
Medium
Product:
FOS
Technology:
Monitoring/RAS
Reported In Release:
FOS7.3.0
Technology Area:
Equipment Status
Symptom:
FC16-64 DC power consumption is set to 160W but needs to be lowered to its actual maximum.
Condition:
FC16-64 is inserted in a 8510-8 or 8510-4 chassis, slotshow -p will display DC power consumption as
160W.