9 SDN Commands The following commands are for Software Defined Networking (SDN) OpenFlow commands. • connect retry-interval • controller • debug openflow packets • flow-map • interface-type • learning-switch-assist • multiple-fwd-table • of-instance (Interface) • openflow of-instance • show openflow • show openflow flows • shutdown connect retry-interval Configure the timed interval (in seconds) that the OpenFlow (OF) instance will wait after requesting a connection with the OpenFlow controller. Z-Series, S4810 Syntax Parameter connect retry-interval interval interval Enter the number of seconds the OF instance will wait after attempting to establish a connection with OF controller. Range is 10- 60. Defaults Command Modes Command History 15 (seconds) OPENFLOW INSTANCE Version 9.1(0.0) Introduced on Z9000 and S4810. Usage Information Related Commands After the interval time lapses, the OpenFlow instance will reattempt to establish a connection to the OpenFlow controller. openflow of-instance Create or modify an OpenFlow instance. 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

9
SDN Commands
The following commands are for Software Defined Networking (SDN) OpenFlow commands.
connect retry-interval
controller
debug openflow packets
flow-map
interface-type
learning-switch-assist
multiple-fwd-table
of-instance (Interface)
openflow of-instance
show openflow
show openflow flows
shutdown
connect retry-interval
Configure the timed interval (in seconds) that the OpenFlow (OF) instance will wait after requesting a connection with
the OpenFlow controller.
Z-Series, S4810
Syntax
connect retry-interval
interval
Parameter
interval
Enter the number of seconds the OF instance will wait after
attempting to establish a connection with OF controller. Range is 10–
60.
Defaults
15 (seconds)
Command Modes
OPENFLOW INSTANCE
Command History
Version 9.1(0.0)
Introduced on Z9000 and S4810.
Usage
Information
After the interval time lapses, the OpenFlow instance will reattempt to establish a connection
to the OpenFlow controller.
Related
Commands
openflow of-instance
Create or modify an OpenFlow instance.