Dell Force10 Software Defined Networking Software-Defined Networking (SDN) Dep - Page 33

openflow of-instance, Z-Series, S4810

Page 33 highlights

• GVRP • IPv4 • IPv6 • MAC • MTU • Spanning-tree protocols • Switchport Related Commands openflow of-instance Create or modify an OpenFlow instance. openflow of-instance Create an OpenFlow (OF) instance or modify an existing OpenFlow instance. Z-Series, S4810 Syntax Parameters Defaults Command Modes Command History openflow of-instance of-id of-id Enter the number of the OF instance. Range is 1 to 8. If you are creating a new OF instance, enter the number you want to assign to the OF instance. If you are modifying an existing OF instance, enter the number of the instance you want to change. NOTE: You must disable the OF instance before making any configuration changes. none CONFIGURATION Version 9.1(0.0) Introduced on Z9000 and S4810. Usage Information • Stacking for S4810, controller High Availability, and VLT are not supported on OF instances. • To enable OpenFlow on S4810, the stack unit number must be zero. • Up to eight OF instances can be created. • To establish a connection with the controller, you must enable the OF instance using the no shutdown command. • To modify the OF instance, you must disable the OF instance first using the shutdown command. • One controller IP and one TCP port can be configured for each OF instance. • The number of supported flows depends on the flow type. The following table provides the number of supported flows for each flow type: Flow Type ACL Maximum Number of Available Flows 256 or 512 (depending on ACL CAM carving) 33

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36

GVRP
IPv4
IPv6
MAC
MTU
Spanning-tree protocols
Switchport
Related
Commands
openflow of-instance
Create or modify an OpenFlow instance.
openflow of-instance
Create an OpenFlow (OF) instance or modify an existing OpenFlow instance.
Z-Series, S4810
Syntax
openflow of-instance
of-id
Parameters
of-id
Enter the number of the OF instance. Range is 1 to 8.
If you are creating a new OF instance, enter the number you want to assign to the OF instance.
If you are modifying an existing OF instance, enter the number of the instance you want to
change.
NOTE:
You must disable the OF instance before making any configuration changes.
Defaults
none
Command Modes
CONFIGURATION
Command History
Version 9.1(0.0)
Introduced on Z9000 and S4810.
Usage
Information
Stacking for S4810, controller High Availability, and VLT are not supported on OF
instances.
To enable OpenFlow on S4810, the stack unit number must be zero.
Up to eight OF instances can be created.
To establish a connection with the controller, you must enable the OF instance using
the
no shutdown
command.
To modify the OF instance, you must disable the OF instance first using the
shutdown
command.
One controller IP and one TCP port can be configured for each OF instance.
The number of supported flows depends on the flow type. The following table provides
the number of supported flows for each flow type:
Flow Type
Maximum Number of Available Flows
ACL
256 or 512 (depending on ACL CAM carving)
33