Dell N3200-ON Networking N-Series Switches RESTful API User Guide version 6.8. - Page 215
Table 4, System Misc UPDATE Request Details, Parameter, Description
View all Dell N3200-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 215 highlights
"error_code": -22 } } System Misc UPDATE PUT /open/v1/systemmisc Use this call to update various miscellaneous system settings. Use GET (see preceding example) to determine allowed lengths via the hostnameSize and systemPromptMaxSize attributes. Request Details Table 4-132. System Misc UPDATE Request Details Parameter systemPrompt hostname Type string string Description System prompt (optional). Hostname (optional). NOTE: At least one of the optional arguments must be specified, otherwise a 400 response and an OPEN_E_PARAM error code will be returned. Response Details HTTP Response Codes The possible HTTP Response codes are 200, 400, and 500. Internal Error Codes The possible error codes for OpEN API are shown in the following table. Table 4-133. System Misc UPDATE Internal Error Codes Error Code 0 -22 -26 Code Name OPEN_E_NONE OPEN_E_PARAM OPEN_E_FAIL Description Update successful. Error in parameters passed, or none of the optional parameters was specified. Update failed. Rest API Reference 215