Dell PowerConnect Brocade 6510 Hardware Reference - Page 17

Platform components, Port side of the Brocade 6510 - brocade firmware download

Page 17 highlights

Port side of the Brocade 6510 1 • Real time power monitoring enables users to monitor real time power usage of the fabric at a switch level. • Port-to-port latency minimized to 800 nanoseconds through the use of cut-through frame routing at 16 Gbps. Platform components • A system motherboard that features a PowerPC 440EPx Reduced Instruction Set Computer (RISC) CPU running at 667 MHz, with integrated peripherals, and that provides high performance with low power consumption. • An RJ45 10/100 Bast T Ethernet system management port, in conjunction with EZSwitchSetup, that supports switch IP address discovery and configuration, eliminating the need to attach a serial cable to configure the switch IP address and greatly increasing the ease of use. • One RS-232 serial port with RJ45 connector for initial switch setup (if not using EZSwitch Setup) and factory default restoration. (the integral LEDs remain unlit at all times) • A USB port that provides storage for firmware updates, output of the supportSave command and storage for configuration uploads and downloads. • Two hot-swappable, redundant power supply and fan FRUs. There are two fans per FRU. • Rack-mount design (1U form factor) in a 19-inch EIA rack. • One LED (green/amber) per FC port to indicate status. • One LED (green) for system power. • One LED (green/amber) for system status. • Two Ethernet LEDs (integrated with RJ45) for speed and activity status. • SEEPROM for switch identification. • Voltage monitoring. • Fan monitoring including flow direction. • Temperature monitoring. • Real-time clock (RTC) with battery. • The Brocade EZSwitchSetup wizard that makes SAN configuration a three-step point-and-click task. Port side of the Brocade 6510 The port side of the Brocade 6510 includes the system status LED, console port, Ethernet port and LEDs, USB port, and Fibre Channel ports and the corresponding port status LEDs. Figure 1 shows the port side of the Brocade 6510. Brocade 6510 Hardware Reference Manual 3 53-1002174-06

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62

Brocade 6510 Hardware Reference Manual
3
53-1002174-06
Port side of the Brocade 6510
1
Real time power monitoring enables users to monitor real time power usage of the fabric at a
switch level.
Port-to-port latency minimized to 800 nanoseconds through the use of cut-through frame
routing at 16 Gbps.
Platform components
A system motherboard that features a PowerPC 440EPx Reduced Instruction Set Computer
(RISC) CPU running at 667 MHz, with integrated peripherals, and that provides high
performance with low power consumption.
An RJ45 10/100 Bast T Ethernet system management port, in conjunction with
EZSwitchSetup, that supports switch IP address discovery and configuration, eliminating the
need to attach a serial cable to configure the switch IP address and greatly increasing the ease
of use.
One RS-232 serial port with RJ45 connector for initial switch setup (if not using EZSwitch
Setup) and factory default restoration. (the integral LEDs remain unlit at all times)
A USB port that provides storage for firmware updates, output of the
supportSave
command
and storage for configuration uploads and downloads.
Two hot-swappable, redundant power supply and fan FRUs. There are two fans per FRU.
Rack-mount design (1U form factor) in a 19-inch EIA rack.
One LED (green/amber) per FC port to indicate status.
One LED (green) for system power.
One LED (green/amber) for system status.
Two Ethernet LEDs (integrated with RJ45) for speed and activity status.
SEEPROM for switch identification.
Voltage monitoring.
Fan monitoring including flow direction.
Temperature monitoring.
Real-time clock (RTC) with battery.
The Brocade EZSwitchSetup wizard that makes SAN configuration a three-step point-and-click
task.
Port side of the Brocade 6510
The port side of the Brocade 6510 includes the system status LED, console port, Ethernet port and
LEDs, USB port, and Fibre Channel ports and the corresponding port status LEDs.
Figure 1