Dell PowerEdge C6220 Using the Baseboard Management Controller - Page 51
IPMI 1.5/2.0 Command Support List - specs
View all Dell PowerEdge C6220 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 51 highlights
FILE LOCATION: D:\Projects\Service Guide\Server\2011_Scorpion\RIS\BMC Manual\BMC\C6220_BMC_HOM_section1.fm IPMI 1.5/2.0 Command Support List The IPMItool program provides a simple command-line interface for managing IPMI-enabled devices. The IPMItool enables you to read the BMC devices, BMC watchdog timer, PEF/PET alerts, SDR, events, SEL, FRU information, serial/modem devices, set LAN configuration parameters, update the BMC firmware remotely and perform remote server chassis or sled server power control. NOTE: For more information about the standard IPMI tool commands, see ipmitool.sourceforge.net/manpage.html. The following tables include all commands defined in the IPMI v2.0 specifications. All mandatory commands and some optional functions are supported. Special functions beyond the scope of IPMI v2.0 are implemented as original equipment manufacturer (OEM) commands. In the O/M column: • M = Mandatory in the IPMI spec and is implemented. • O = Optional command supported in this implementation. • N = Not supported in this implementation. See the Deployment Toolkit Version 1.3 User's Guide for additional information about installing and using the DTK utilities, and the Deployment Toolkit Version 1.3 Command Line Interface Reference Guide for a complete list of all valid options, suboptions, and arguments for using the BMCCFG.EXE to configure and manage your BMC. NOTE: For a complete list of all valid options, requirements, and commands refer to the BMC Firmware Requirements for DCS/PE-C 1.02 documentation. 51