Dell PowerEdge C6420 EMC Technical Specifications 1 - Page 8

Environmental specifications, Standard operating temperature specifications - datasheet

Page 8 highlights

Environmental specifications The sections below contains information about the environmental specifications of the system. NOTE: For additional information about environmental certifications, please refer to the Product Environmental Datasheet located with the Manuals & Documents on www.dell.com/poweredgemanuals Standard operating temperature specifications NOTE: 1. Not available: Indicates that the configuration is not offered by Dell EMC. 2. Not supported: Indicates that the configuration is not thermally supported. NOTE: All components including the DIMMs, communication cards, M.2 SATA, and PERC cards can be supported with sufficient thermal margin if the ambient temperature is equal to or below to the maximum continuous operating temperature listed in these tables except for the Mellanox DP LP card and Intel Rush Creek card. Table 8. Standard operating temperature specifications Standard operating temperature Temperature ranges (for altitude less than 950 m or 3117 ft) Specifications 10°C-35°C (50°F-95°F) with no direct sunlight on the equipment. NOTE: Some configurations require a lower ambient temperature. For more information, see the following tables. Table 9. Maximum continuous operating temperature for nonfabric dual processor configuration TDP Process Watts or model 8280 8280L 205 W 8280M 8270 8268 200 W 6254 Heat sink model CPU1: FMM2M | CPU2: V2DRD CPU1: FMM2M | CPU2: V2DRD CPU1: FMM2M | CPU2: V2DRD CPU1: FMM2M | CPU2: V2DRD CPU1: FMM2M | CPU2: V2DRD CPU1: FMM2M | CPU2: V2DRD Max 3.5-inch chassis memor y/ proces 12x sor Drives 8x Drive s 4x Drive s 24x Drive s 2.5-inch chassis 20x Driv es 16x Drives 12x Drive s 8x Driv es 4x Drive s CPU1: 6 | CPU2: 8 20 21 21 21 21 CPU1: 6 | CPU2: 20 21 8 CPU1: 6 | CPU2: 8 Not Suppor ted (2°C) Not Suppo rted (10°C ) Not Supp orted (11°C ) Not Supp orte d(19° C) 20 21 CPU1: 6 | CPU2: 8 20 21 21 21 21 21 21 21 21 21 21 CPU1: 6 | CPU2: 8 20 21 21 21 21 CPU1: Not Not Not 6 | Suppor Suppo Supp CPU2: ted(6° rted(1 orted( 20 21 22 22 22 22 8 C) 4°C) 15°C) No-BP Chassis N/A 30 30 30 30 30 30 8 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23

Environmental specifications
The sections below contains information about the environmental specifications of the system.
NOTE:
For additional information about environmental certifications, please refer to the Product Environmental
Datasheet located with the Manuals & Documents on
www.dell.com/poweredgemanuals
Standard operating temperature specifications
NOTE:
1.
Not available: Indicates that the configuration is not offered by Dell EMC.
2.
Not supported: Indicates that the configuration is not thermally supported.
NOTE:
All components including the DIMMs, communication cards, M.2 SATA, and PERC cards can be supported with
sufficient thermal margin if the ambient temperature is equal to or below to the maximum continuous operating
temperature listed in these tables except for the Mellanox DP LP card and Intel Rush Creek card.
Table 8. Standard operating temperature specifications
Standard operating temperature
Specifications
Temperature ranges (for altitude less than 950 m or 3117 ft)
10°C–35°C (50°F–95°F) with no direct sunlight on the
equipment.
NOTE:
Some configurations require a lower ambient temperature. For more information, see the following tables.
Table 9. Maximum continuous operating temperature for nonfabric dual processor configuration
TDP
Watts
Process
or model
Heat sink
model
Max
memor
y/
proces
sor
3.5-inch chassis
2.5-inch chassis
No-BP
Chassis
12x
Drives
8x
Drive
s
4x
Drive
s
24x
Drive
s
20x
Driv
es
16x
Drives
12x
Drive
s
8x
Driv
es
4x
Drive
s
N/A
205 W
8280
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1:
6 |
CPU2:
8
Not
Suppor
ted
(2°C)
Not
Suppo
rted
(10°C
)
Not
Supp
orted
(11°C
)
Not
Supp
orte
d(19°
C)
20
21
21
21
21
30
8280L
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1:
6 |
CPU2:
8
20
21
21
21
21
30
8280M
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1:
6 |
CPU2:
8
20
21
21
21
21
30
8270
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1:
6 |
CPU2:
8
20
21
21
21
21
30
8268
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1:
6 |
CPU2:
8
20
21
21
21
21
30
200 W
6254
CPU1:
FMM2M |
CPU2:
V2DRD
CPU1:
6 |
CPU2:
8
Not
Suppor
ted(6°
C)
Not
Suppo
rted(1
4°C)
Not
Supp
orted(
15°C)
20
21
22
22
22
22
30
8
Technical specifications