Dell PowerEdge External Media System 1434 Improving NFS performance on HPC clu - Page 3

Contents, Appendix A: Step-by-step configuration of Dell Fluid Cache for NFS

Page 3 highlights

Improving NFS Performance on HPC Clusters with Dell Fluid Cache for DAS Contents Executive Summary ...5 1. Introduction...6 1.1. Dell Fluid Cache for DAS (direct-attached storage 6 2. Solution design and architecture 6 2.1. NFS storage solution (baseline 7 2.2. Dell Fluid Cache for DAS based solution 9 2.3. I/O clients test bed 10 2.4. Solution tuning 12 2.4.1. Storage 13 2.4.2. NFS server 13 2.4.3. Dell Fluid Cache for DAS 14 2.5. Tracking solution health and performance 14 2.5.1. Server health and monitoring 14 2.5.2. Dell PowerEdge Express Flash PCIe SSD health and monitoring 14 2.5.3. Dell Fluid Cache for DAS health and monitoring 16 3. Performance ...16 3.1. Sequential writes and reads 17 3.2. Random writes and reads 19 3.3. Metadata tests 20 3.4. Cold-cache tests 22 4. Conclusion...25 5. References ...25 Appendix A: Step-by-step configuration of Dell Fluid Cache for NFS 27 A.1. Hardware checklist and cabling 27 A.2. NFS server set up 28 A.3. NFS server configuration and tuning 29 A.4. Virtual disk configuration 31 A.5. XFS and DFC configuration 33 A.6. Useful commands and references 34 A.7. Performance tuning on clients 34 Appendix B: Benchmarks and tests 35 B.1. IOzone ...35 B.2. mdtest...37 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

Improving NFS Performance on HPC Clusters with Dell Fluid Cache for DAS
3
Contents
Executive Summary
.......................................................................................................
5
1.
Introduction
...........................................................................................................
6
1.1.
Dell Fluid Cache for DAS (direct-attached storage)
.....................................................
6
2.
Solution design and architecture
..................................................................................
6
2.1.
NFS storage solution (baseline)
.............................................................................
7
2.2.
Dell Fluid Cache for DAS based solution
..................................................................
9
2.3.
I/O clients test bed
.........................................................................................
10
2.4.
Solution tuning
...............................................................................................
12
2.4.1.
Storage
..................................................................................................
13
2.4.2.
NFS server
..............................................................................................
13
2.4.3.
Dell Fluid Cache for DAS
.............................................................................
14
2.5.
Tracking solution health and performance
.............................................................
14
2.5.1.
Server health and monitoring
.......................................................................
14
2.5.2.
Dell PowerEdge Express Flash PCIe SSD health and monitoring
..............................
14
2.5.3.
Dell Fluid Cache for DAS health and monitoring
.................................................
16
3.
Performance
........................................................................................................
16
3.1.
Sequential writes and reads
...............................................................................
17
3.2.
Random writes and reads
..................................................................................
19
3.3.
Metadata tests
...............................................................................................
20
3.4.
Cold-cache tests
.............................................................................................
22
4.
Conclusion
...........................................................................................................
25
5.
References
..........................................................................................................
25
Appendix A: Step-by-step configuration of Dell Fluid Cache for NFS
..........................................
27
A.1.
Hardware checklist and cabling
..........................................................................
27
A.2.
NFS server set up
............................................................................................
28
A.3.
NFS server configuration and tuning
.....................................................................
29
A.4.
Virtual disk configuration
..................................................................................
31
A.5.
XFS and DFC configuration
.................................................................................
33
A.6.
Useful commands and references
........................................................................
34
A.7.
Performance tuning on clients
............................................................................
34
Appendix B: Benchmarks and tests
...................................................................................
35
B.1.
IOzone
.........................................................................................................
35
B.2.
mdtest
.........................................................................................................
37