Dell PowerEdge M520 Dell 10 Gb Ethernet Pass Through-k  for M1000e So - Page 15

Port Commands

Page 15 highlights

Rev 1.00 3.5 Port Commands 3.5.1 show port link Synopsys: show port link [port_number] Description: This command displays detailed port information. If an uplink port number is specified ([port_number]), then the command displays information only for this port; otherwise, the command displays information for all the ports. The command displays the following information per port: • Port number • Port group identifier and speed: A, B, followed by the configured speed (10G) • Pass through connection status, may have one of the following values: down - either uplink or downlink is not connected mismatch - both uplink and downlink are connected, but there is a mismatch 10G - uplink and downlink are connected at 10GbE • Downlink port link state: - down: blade not present - 10G: 10GbE link • Uplink port link state: - empty: No module present - module_type [no link]: Module is present (module type is shown); no link: optical fiber cable is disconnected Example: # show port link Port Group Connect Downlink Uplink Status 1 A (10G) 10G 10G SFP+ SR Link Up 2 A (10G) 10G 10G SFP+ SR Link Up 3 A (10G) 10G 10G SFP+ LR Link Up 4 A (10G) 10G 10G SFP+ SR Link Up 5 A (10G) 10G 10G SFP+ SR Link Up 6 A (10G) mismatch 10G SFP SX Link Down 7 A (10G) down down SFP+ SR Link Down 8 A (10G) down down empty 9 B (10G) mismatch 10G SFP SX Link Down 10 B (10G) mismatch 10G SFP SX Link Down 11 B (10G) mismatch 10G SFP SX Link Down 12 B (10G) mismatch 10G SFP LX Link Down 13 B (10G) down down empty 14 B (10G) down 10G SFP+ SR Link Down 15 B (10G) mismatch 1G SFP+ SR Link Down 16 B (10G) mismatch 1G SFP+ SR Link Down 15

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Rev 1.00
15
3.5
Port Commands
3.5.1
show port link
Synopsys:
show port link [
port_number
]
Description:
This command displays detailed port information. If an uplink port number is specified
([port_number]), then the command displays information only for this port; otherwise, the com-
mand displays information for all the ports.
The command displays the following information per port:
Port number
Port group identifier and speed: A, B, followed by the configured speed (10G)
Pass through connection status, may have one of the following values:
down - either uplink or downlink is not connected
mismatch - both uplink and downlink are connected, but there is a mismatch
10G - uplink and downlink are connected at 10GbE
Downlink port link state:
-
down: blade not present
-
10G: 10GbE link
Uplink port link state:
-
empty: No module present
-
module_type [no link]: Module is present (module type is shown);
no link: optical fiber cable is disconnected
Example:
# show port link
Port Group
Connect
Downlink
Uplink
Status
--------------------------------------------------------------
1
A (10G)
10G
10G
SFP+ SR
Link Up
2
A (10G)
10G
10G
SFP+ SR
Link Up
3
A (10G)
10G
10G
SFP+ LR
Link Up
4
A (10G)
10G
10G
SFP+ SR
Link Up
5
A (10G)
10G
10G
SFP+ SR
Link Up
6
A (10G)
mismatch
10G
SFP SX
Link Down
7
A (10G)
down
down
SFP+ SR
Link Down
8
A (10G)
down
down
empty
9
B (10G)
mismatch
10G
SFP SX
Link Down
10
B (10G)
mismatch
10G
SFP SX
Link Down
11
B (10G)
mismatch
10G
SFP SX
Link Down
12
B (10G)
mismatch
10G
SFP LX
Link Down
13
B (10G)
down
down
empty
14
B (10G)
down
10G
SFP+ SR
Link Down
15
B (10G)
mismatch
1G
SFP+ SR
Link Down
16
B (10G)
mismatch
1G
SFP+ SR
Link Down