Dell PowerEdge R940xa EMC Technical Specifications - Page 27

Expanded operating temperature restrictions, Fresh air restrictions, Processors, Number of, drives

Page 27 highlights

• Comprehensive thermal management: The thermal control system regulates the system fan speeds based on feedback from system component temperature sensors, as well as for system inventory and subsystem power draw. Temperature monitoring includes components such as processors, DIMMs, chipset, system inlet air ambient, hard disk drives, NDC, and GPU. • Open and closed loop fan speed control: Open loop fan control uses system configuration to determine fan speed based on system inlet air temperature. Closed loop thermal control uses temperature feedback to dynamically adjust fan speeds based on system activity and cooling requirements. • User-configurable settings: With the understanding and realization that every customer has a unique set of circumstances or expectations from the system, in this generation of servers, we have introduced limited user-configurable settings in the iDRAC9 BIOS setup screen. For more information, see the Dell EMC PowerEdge system Installation and Service Manual on Dell.com/Support/ Manuals and "Advanced Thermal Control: Optimizing across Environments and Power Goals" on Dell.com. • Cooling redundancy: The system allows N+1 fan redundancy, allowing continuous operation with one fan failure in the system. • Environmental Specifications: The optimized thermal management makes the R940xa reliable under a wide range of operating environments. Expanded operating temperature restrictions • The operating temperature is for a maximum altitude of 950 m for fresh air cooling • No cold start-ups below 5°C due to hard drive constraints • Apache Pass DIMM, NVDIMM, PCIeSSD and NVME are not supported • GPGPU configuration are not supported • LRDIMM > 32 GB are not supported in x4 socket configurations • DCPMMs are not supported. • Redundant power supply units are required • Non Dell qualified peripheral cards and /or peripheral cards greater than 25 W are not supported • Intel FPGA is not supported • Mellanox CX5 is not supported Fresh air restrictions Following table lists the configuration required for efficient cooling. Table 19. Fresh air restriction matrix Processors Number of Processor/ GPUs Number of drives Ambient temperatur e Fresh air support Fan type Processors Up to 304W Up to 304W processor processor (CPU 1/2) (CPU 3/4) Shroud All GPU/2&4 32x2.5-inch, 30 No AEP Six standard 4U height Remove the CPU w/ NVMe 2U height HSK air shroud A HSK (L-shape) All No 32x2.5-inch, 35 No AEP Six standard 4U height Install the air GPU /2&4 w/ NVMe 2U height HSK shroud A CPU HSK (L-shape) 205W / 200W / 165W_12C / 150W_8C CPU No GPU /4 CPU 32x2.5-inch, 35 w/o NVMe No AEP Six standard 2U height HSK 4U height Install the air HSK shroud A (L-shape) Processor TDP 32G Six standard 2U height HSK 4U height Install the air HSK shroud A (L-shape) Technical specifications 27

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

Comprehensive thermal management: The thermal control system regulates the system fan speeds based on feedback from system
component temperature sensors, as well as for system inventory and subsystem power draw. Temperature monitoring includes
components such as processors, DIMMs, chipset, system inlet air ambient, hard disk drives, NDC, and GPU.
Open and closed loop fan speed control: Open loop fan control uses system configuration to determine fan speed based on system
inlet air temperature. Closed loop thermal control uses temperature feedback to dynamically adjust fan speeds based on system
activity and cooling requirements.
User-configurable settings: With the understanding and realization that every customer has a unique set of circumstances or
expectations from the system, in this generation of servers, we have introduced limited user-configurable settings in the iDRAC9 BIOS
setup screen. For more information, see the Dell EMC PowerEdge system Installation and Service Manual on Dell.com/Support/
Manuals and “Advanced Thermal Control: Optimizing across Environments and Power Goals” on Dell.com.
Cooling redundancy: The system allows N+1 fan redundancy, allowing continuous operation with one fan failure in the system.
Environmental Specifications: The optimized thermal management makes the R940xa reliable under a wide range of operating
environments.
Expanded operating temperature restrictions
The operating temperature is for a maximum altitude of 950 m for fresh air cooling
No cold start-ups below 5°C due to hard drive constraints
Apache Pass DIMM, NVDIMM, PCIeSSD and NVME are not supported
GPGPU configuration are not supported
LRDIMM > 32 GB are not supported in x4 socket configurations
DCPMMs are not supported.
Redundant power supply units are required
Non Dell qualified peripheral cards and /or peripheral cards greater than 25 W are not supported
Intel FPGA is not supported
Mellanox CX5 is not supported
Fresh air restrictions
Following table lists the configuration required for efficient cooling.
Table 19. Fresh air restriction matrix
Processors
Number of
Processor/
GPUs
Number of
drives
Ambient
temperatur
e
Fresh air
support
Fan type
Processors
Shroud
Up to 304W
processor
(CPU 1/2)
Up to 304W
processor
(CPU 3/4)
All
GPU/2&4
CPU
32x2.5-inch,
w/ NVMe
30
No AEP
Six standard
2U height
HSK
4U height
HSK
Remove the
air shroud A
(L-shape)
All
No
GPU /2&4
CPU
32x2.5-inch,
w/ NVMe
35
No AEP
Six standard
2U height
HSK
4U height
HSK
Install the air
shroud A
(L-shape)
205W /
200W /
165W_12C /
150W_8C
CPU
No GPU /4
CPU
32x2.5-inch,
w/o NVMe
35
No AEP
Six standard
2U height
HSK
4U height
HSK
Install the air
shroud A
(L-shape)
Processor
TDP <=
165W
No GPU /4
CPU
32x2.5-inch,
w/o NVMe
C40E45
Non-support
FA with
GPU, AEP,
NVDIMM,
PCIeSSD,
NVMe and
INTEL
FPGALRDIM
M > 32G
Six standard
2U height
HSK
4U height
HSK
Install the air
shroud A
(L-shape)
Technical specifications
27