Standard operating temperature, Expanded operating temperature
View all Dell PowerEdge T440 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 11 highlights
Table 10. Maximum shock specifications Maximum shock Operating Storage Specifications Six consecutively executed shock pulses in the positive and negative x, y, and z axes of 6 G for up to 11 ms. 6 consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 71 G for up to 2 ms. Table 11. Maximum altitude specifications Maximum altitude Operating Storage Specifications 3048 m (10,000 ft) 12,000 m (39,370 ft) Table 12. Operating temperature derating specifications Operating temperature derating Up to 35°C (95°F) 35 °C-40°C (95 °F-104°F) 40 °C-45°C (104 °F-113°F) Specifications Maximum temperature reduces by 1°C/300 m (1°F/547 ft) above 950 m (3,117 ft). Maximum temperature reduces by 1°C/175 m (1°F/319 ft) above 950 m (3,117 ft). Maximum temperature reduces by 1°C/125 m (1°F/228 ft) above 950 m (3,117 ft). Standard operating temperature Table 13. Standard operating temperature specifications Standard operating temperature Specifications Continuous operation (for altitude less than 950 m or 3117 10°C-35°C (50°F-95°F) with no direct sunlight on the equipment. ft) Expanded operating temperature Table 14. Expanded operating temperature specifications Expanded operating temperature Specifications Continuous operation 5°C-40°C at 5% to 85% RH with 29°C dew point. NOTE: Outside the standard operating temperature (10°C-35°C), the system can operate continuously in temperatures as low as 5°C and as high as 40°C. Technical specifications 11