Dell PowerEdge T550 EMC Technical Specifications - Page 14

Particulate and gaseous contamination specifications

Page 14 highlights

8x, 16x, 24x 2.5-inch SAS/SATA Configuration 1 8x 3.5-inch Configuration 2 120 W 125 W 135 W 150 W 165 W 185 W 205 W 220 W STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK Not supporte d Not supporte d STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK HPR HSK HPR HSK STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK HPR HSK HPR HSK STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK HPR HSK HPR HSK STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK Not supporte d Not supporte d STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK HPR HSK HPR HSK STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK HPR HSK HPR HSK STD HSK STD HSK STD HSK STD HSK HPR HSK HPR HSK HPR HSK HPR HSK 8x 3.5-inch + 8x 2.5-inch NVMe Configuration 3 STD STD HSK HSK STD STD HSK HSK STD STD HSK HSK STD STD HSK HSK HPR HSK HPR HSK HPR HSK HPR HSK HPR HSK HPR HSK HPR HSK HPR HSK Particulate and gaseous contamination specifications The following table defines the limitations that help avoid any damages to the IT equipment and/or, or both failure from particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions is the responsibility of the customer. Table 21. Particulate contamination specifications Particulate contamination Air filtration Specifications Data center air filtration as defined by ISO Class 8 per ISO 14644-1 with a 95% upper confidence limit. NOTE: This condition applies to data center environments only. Air filtration requirements do not apply to IT equipment designed to be used outside a data center, in environments such as an office or factory floor. NOTE: Air entering the data center must have MERV11 or MERV13 filtration. Conductive dust Air must be free of conductive dust, zinc whiskers, or other conductive particles. NOTE: This condition applies to data center and non-data center environments. Corrosive dust ● Air must be free of corrosive dust. ● Residual dust present in the air must have a deliquescent point less than 60% relative humidity. NOTE: This condition applies to data center and non-data center environments. 14 Technical specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

8x, 16x, 24x 2.5-inch SAS/SATA
Configuration 1
8x 3.5-inch Configuration 2
8x 3.5-inch + 8x
2.5-inch NVMe
Configuration 3
120 W
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
125 W
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
135 W
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
150 W
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
STD
HSK
165 W
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
185 W
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
205 W
Not
supporte
d
HPR
HSK
HPR
HSK
HPR
HSK
Not
supporte
d
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
220 W
Not
supporte
d
HPR
HSK
HPR
HSK
HPR
HSK
Not
supporte
d
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
HPR
HSK
Particulate and gaseous contamination specifications
The following table defines the limitations that help avoid any damages to the IT equipment and/or, or both failure from
particulate and gaseous contamination. If the levels of particulate or gaseous pollution exceed the specified limitations and
results in equipment damage or failure, you must rectify the environmental conditions. Remediation of environmental conditions
is the responsibility of the customer.
Table 21. Particulate contamination specifications
Particulate contamination
Specifications
Air filtration
Data center air filtration as defined by ISO Class 8 per ISO
14644-1 with a 95% upper confidence limit.
NOTE:
This condition applies to data center environments
only. Air filtration requirements do not apply to IT
equipment designed to be used outside a data center, in
environments such as an office or factory floor.
NOTE:
Air entering the data center must have MERV11 or
MERV13 filtration.
Conductive dust
Air must be free of conductive dust, zinc whiskers, or other
conductive particles.
NOTE:
This condition applies to data center and non-data
center environments.
Corrosive dust
Air must be free of corrosive dust.
Residual dust present in the air must have a deliquescent
point less than 60% relative humidity.
NOTE:
This condition applies to data center and non-data
center environments.
14
Technical specifications