Dell PowerEdge T620 Technical Guide - Page 31

Energy Smart Solution Advisor ESSA - noise

Page 31 highlights

Lower overall system-level power draw is a result of Dell's breakthrough system design. PowerEdge servers maximize performance per watt through a combination of power and cooling, energy efficient technologies and tools. Additionally, PowerEdge servers have an extensive collection of sensors that automatically track thermal activity, which helps regulate temperature thereby reducing server noise and power consumption. With the rise in the cost of energy coupled with increasing data center density, Dell provides tools and technologies to help you realize greater performance with less energy cost and waste. More efficient data center usage can reduce costs by slowing the need for additional center space. Table 19 lists the tools and technologies Dell offers to help you achieve your data center goals by lowering power consumption and increasing energy efficiency. Feature Power supply units (PSU) portfolio Tools for right-sizing Industry compliance Power monitoring accuracy Power capping Description Dell's PSU portfolio includes intelligent features such as dynamically optimizing efficiency while maintaining availability and redundancy. Find additional information in the Power supply units section. Energy Smart Solution Advisor (ESSA) is a tool that helps you determine the most efficient configuration possible. With ESSA, you can calculate the power consumption of your hardware, power infrastructure, and storage. ESSA can help you determine exactly how much power your server will use at a given workload, and the PSU Advisor can help you choose the best, most efficient PSU for your workload. Learn more at Dell.com/calc. Energy Smart Data Center Assessment is a Dell Services offering that uses infrastructure and thermal analysis to help maximize system efficiency. Learn more at Dell.com/EnergySmart. Dell's servers are compliant with all relevant industry certifications and guidelines, including 80 PLUS, Climate Savers, and ENERGY STAR®. PSU power monitoring improvements include:  Dell's power monitoring accuracy is currently 1%, whereas the industry standard is 5%  More accurate reporting of power  Better performance under a power cap Use Dell's systems management to set the power cap limit for your systems to limit the output of a PSU and reduce system power consumption. Dell is the first hardware vendor to leverage Intel Node Manager for circuit-breaker fast capping.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55

Lower overall system-
level power draw is a result of Dell’s breakthrough system design. PowerEdge
servers maximize performance per watt through a combination of power and cooling, energy
efficient technologies and tools. Additionally, PowerEdge servers have an extensive collection of
sensors that automatically track thermal activity, which helps regulate temperature thereby reducing
server noise and power consumption.
With the rise in the cost of energy coupled with increasing data center density, Dell provides tools
and technologies to help you realize greater performance with less energy cost and waste. More
efficient data center usage can reduce costs by slowing the need for additional center space.
Table 19 lists the tools and technologies Dell offers to help you achieve your data center goals by
lowering power consumption and increasing energy efficiency.
Feature
Description
Power supply units (PSU)
portfolio
Dell’s PSU portfolio include
s intelligent features such as dynamically
optimizing efficiency while maintaining availability and redundancy. Find
additional information in the Power supply units section.
Tools for right-sizing
Energy Smart Solution Advisor (ESSA)
is a tool that helps you determine the
most efficient configuration possible. With ESSA, you can calculate the
power consumption of your hardware, power infrastructure, and storage.
ESSA can help you determine exactly how much power your server will use
at a given workload, and the PSU Advisor can help you choose the best,
most efficient PSU for your workload. Learn more at
Dell.com/calc
.
Energy Smart Data Center Assessment
is a Dell Services offering that uses
infrastructure and thermal analysis to help maximize system efficiency. Learn
more at
Dell.com/EnergySmart
.
Industry compliance
Dell’s servers are c
ompliant with all relevant industry certifications and
guidelines, including 80 PLUS, Climate Savers, and
ENERGY STAR
®
.
Power monitoring
accuracy
PSU power monitoring improvements include:
Dell’s
power monitoring accuracy is
currently 1%, whereas the industry
standard is 5%
More accurate reporting of power
Better performance under a power cap
Power capping
Use Dell’s systems management to set the power cap limit for your systems
to limit the output of a PSU and reduce system power consumption. Dell is
the first hardware vendor to leverage Intel Node Manager for
circuit-breaker fast capping.