Dell PowerEdge T620 Technical Guide - Page 50
Operating, Storage, Current consumption, Supply voltage, Frequency, Heat dissipation BTU/hr max, - dimensions
View all Dell PowerEdge T620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Maximum shock Operating Storage Half sine shock in all operational orientations of 31G +/- 5% with a pulse duration of 2.6ms +/- 10% Half sine shock on all six sides of 71G +/- 5% with a pulse duration of 2ms +/-10%; square wave shock on all six sides of 27G with velocity change at 235 in/sec or greater Altitude Operating Storage -15.2m to 3048m (-50 ft to 10,000 ft) -15.2m to 12,000m (-50 ft to 39,370 ft) Airborne contaminant level Class G1 or lower as defined by ISA-S71.04-1985 Table 31 lists power supply specifications for the PowerEdge T620. Specification 1100W DC 1100W AC 750W AC 495W AC Current consumption Supply voltage 32A -48V to -60V DC 12A-6.5A 100-240VAC1 10A-5A 100-240VAC1 6.5A-3A 100-240VAC1 Frequency N/A 50/60Hz 50/60Hz 50/60Hz Heat dissipation (BTU/hr max) 4416 4100 28432 28913 1908 Maximum inrush current4 55A 55A 55A 55A 1Auto-ranging 2Titanium efficiency 3Platinum efficiency 4Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 55A per power supply for 10ms or less. Table 32 lists the spacing dimensions for the T620 sliding rails. System T620 Rail Identifier Rail Type C2 Sliding Rail Adjustability Range (mm) Rail Depth (mm) Square Min Max Round Min Max Threaded Min Max without CMA with CMA 686 756 672 749 686 771 760 840