Dell PowerVault DL2200 Hardware Owner's Manual - Page 29
Actual Link Width, Plug & Play
View all Dell PowerVault DL2200 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Message Causes No boot sector on Incorrect configuration hard drive. settings in System Setup program, or no operating system on hard drive. No timer tick interrupt. Faulty system board. PCIe Training Faulty or improperly Error: Expected installed PCIe card in the Link Width is x, specified slot. Actual Link Width is y. Plug & Play Configuration Error. Error encountered in initializing PCIe device; faulty system board. Quad rank DIMM Invalid memory detected after configuration. single rank or dual rank DIMM in socket. Corrective Actions Check the hard drive configuration settings in the System Setup program. See "Using the System Setup Program and UEFI Boot Manager" on page 39. If necessary, install the operating system on your hard drive. See your operating system documentation. See "Getting Help" on page 157. Reseat the PCIe card in the specified slot number. See "Troubleshooting Expansion Cards" on page 142. If the problem persists, see "Getting Help" on page 157. Install the NVRAM_CLR jumper in the clear position (pins 1 and 3) and reboot the system. See Figure 6-1 for jumper location. If the problem persists, see "Troubleshooting Expansion Cards" on page 142. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 81. About Your System 29