5 Technical Specifications Physical Disks Physical disks Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS physical disks or 2.5 inch SAS SSDs RAID Controller Modules RAID controller modules Dell PowerVault MD3460 storage arrays Two hot-swappable modules with temperature sensors 4 GB or 8 GB of cache per controller Provides host-to-controller 12 Gbps SAS connection Expansion Modules Dell PowerVault MD3060e expansion enclosures SAS connectors Serial connector (debug port) Supports 120 physical disks, in addition to 60 physical disks in the RAID enclosure Redundant path connectivity provides redundant data paths to each hard drive NOTE: Support for 180 physical disks is a premium feature and requires activation. The maximum number of physical disks supported without using the premium feature is 120. Two SAS IN ports to connect hosts One SAS OUT port for expansion to an additional PowerVault MD3060e expansion enclosure NOTE: SAS connectors are SFF-80644 compliant. Six pin port NOTE: For technical support use only. Back-Panel Connectors (Per RAID Controller Module) SAS connectors Four SAS IN ports to connect hosts Two SAS OUT ports, it is recommended that you use the first port for expansion to an additional PowerVault MD3060e expansion enclosure. Only one expansion port is supported at any given time. 47

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

5
Technical Specifications
Physical Disks
Physical disks
Up to sixty 3.5 inch or 2.5 inch SAS or nearline SAS
physical disks or 2.5 inch SAS SSDs
RAID Controller Modules
RAID controller modules
Two hot-swappable modules with temperature
sensors
4 GB or 8 GB of cache per controller
Dell PowerVault MD3460 storage arrays
Provides host-to-controller 12 Gbps SAS
connection
Expansion Modules
Dell PowerVault MD3060e expansion enclosures
Supports 120 physical disks, in addition to 60
physical disks in the RAID enclosure
Redundant path connectivity provides redundant
data paths to each hard drive
NOTE:
Support for 180 physical disks is a
premium feature and requires activation. The
maximum number of physical disks
supported without using the premium
feature is 120.
SAS connectors
Two SAS IN ports to connect hosts
One SAS OUT port for expansion to an additional
PowerVault MD3060e expansion enclosure
NOTE:
SAS connectors are SFF-80644
compliant.
Serial connector (debug port)
Six pin port
NOTE:
For technical support use only.
Back-Panel Connectors (Per RAID Controller
Module)
SAS connectors
Four SAS IN ports to connect hosts
Two SAS OUT ports, it is recommended that you
use the first port for expansion to an additional
PowerVault MD3060e expansion enclosure. Only
one expansion port is supported at any given time.
47