Dell PowerVault ML6000 Dell PowerVault ML6000 SCSI Reference Guide - Page 79
Report LUNS Response, LUN List Length n-7
View all Dell PowerVault ML6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 79 highlights
Report LUNS Response Table 67 Report LUNS Response Byte Bit 7 6 5 4 3 2 1 0 0 LUN List Length (n-7) 3 4 Reserved 7 8 First LUN 15 n-7 Last LUN n LUN List Length - This field returns the length in bytes of the list of LUNs being returned. LUN - These fields return each available assigned LUN. The information conforms to the Logical Unit Address Method defined in SCC-2, and supports only First Level addressing (for each LUN, only the second byte is used and contains the assigned LUN). PowerVault ML6000 SCSI Reference Guide 69
PowerVault ML6000 SCSI Reference Guide
69
Report LUNS Response
LUN List Length
– This field returns the length in bytes of the list of LUNs being returned.
LUN
– These fields return each available assigned LUN. The information conforms to the Logical Unit
Address Method defined in SCC-2, and supports only First Level addressing (for each LUN, only the second
byte is used and contains the assigned LUN).
Table 67
Report LUNS Response
Bit
Byte
7
6
5
4
3
2
1
0
0
LUN List Length (n-7)
3
4
Reserved
7
8
First LUN
15
n-7
Last LUN
n