Dell PowerVault Storage Area Network Owner's Manual - Page 110
Getting, Getting Help, number
View all Dell PowerVault Storage Area Network manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
Error Code PCI1360 PDR0001 PDR1016 PST0128 PST0129 PSU0001 PSU0002 Message Information Details Action System performance may be degraded, or system may fail to operate. Cycle input power, update component drivers, if device is removable, reinstall the device. Message Details Action A bus fatal error was detected on a component at slot . System performance may be degraded, or system may fail to operate. Cycle input power, update component drivers, if device is removable, reinstall the device. Message Details Action Fault detected on drive . The controller detected a failure on the disk and has taken the disk offline. Remove and re-seat the failed disk. If the issue persists, see Getting Help. Message Details Action Drive is removed from disk drive bay . The controller detected that the drive was removed. Verify drive installation. Re-seat the failed drive. If the issue persists, see Getting Help. Message Details Action No memory is detected. System BIOS was unable to detect memory in the system. Re-seat the memory modules. If the issue persists, see Getting Help. Message Details Action Memory is detected, but is not configurable. System BIOS detected memory, but was unable to configure the memory for system operation. Compare system memory installation to supported system memory configurations. Message Action Power supply failed. Remove and reinstall the power supply. If the issue persists, see Getting Help. Message A predictive failure detected on power supply . 110