Error Code PSU0033 PSU0034 PSU0035 PSU0036 PSU0037 PSU0076 112 Message Information Message Details Action The temperature for power supply is outside of the allowable range. System performance may be degraded. Check the system operating environment, including airflow and inlet temperature. Check system logs for temperature and thermal component failures. Message Details Action An under voltage fault detected on power supply . This failure may be the result of an electrical issue with cables or subsystem components in the system. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage. 3. If the issue persists, see Getting Help. Message Action Message Details Action An over voltage fault detected on power supply . Check input power or reinstall the power supply. If the issue persists, see Getting Help. An over current fault detected on power supply . This failure may be the result of an electrical issue with cables or subsystem components in the system. 1. Remove and reinstall the power supply. 2. Check cables and subsystem components in the system for damage. 3. If the issue persists, see Getting Help. Message Action Message Details Action Fan failure detected on power supply . Check for fan blockage. If the problem persists, see Getting Help. A power supply wattage mismatch is detected; power supply is rated for watts. Power supplies should be of the same input type and power rating. Install matched power supplies and review this manual for proper configuration.