Dell R710 Technical Guide - Page 9

PowerEdge R710 Technical Guide - memory slots

Page 9 highlights

Dell Feature Drive Bays Hard Drive Types External Drive Bay(s) Embedded Hard Drive Controller Optional Storage Controller Availability Server Management I/O Slots R610 R710 R810 6 x 2.5‖ 4 x 3.5" with optional flex bay, 6 x 3.5" without flex bay, or 8 x 2.5‖ 6 x 2.5‖ Hot-plug SAS and SATA, nearline SAS and SSD Hot-plug SAS and SATA, nearline SAS and SSD Hot-plug SAS and SATA, SATA SSD Optional internal Optional flex bay SATA slimline optical drives such as DVD- expansion to support half-height tape N/A ROM or DVD+RW backup unit PERC 6/i, SAS 6/iR, PERC H200, PERC H700 PERC 6/i, SAS 6/iR, PERC H200, PERC H700 PERC H200, PERC H700 Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gps SAS HBA RAID: SAS 6/iR PERC 6/i PERC 6/E PERC H200 PERC H700 PERC H800 Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gps SAS HBA RAID: SAS 6/iR PERC 6/i PERC 6/E PERC H200 PERC H700 PERC H800 Non-RAID: SAS 5/E LSI 2032 (for tape backup unit only) 6Gps SAS HBA RAID: PERC H200 PERC H700 PERC H800 Hot-plug hard drives, hot-plug redundant power and cooling, ECC memory, Single Device Data Correction (SDDC), memory demand and patrol scrubbing, high-availability failover cluster Hot-plug hard drives, hot-plug redundant power and cooling, ECC memory, Single Device Data Correction (SDDC), memory demand and patrol scrubbing, high-availability failover cluster Hot-plug hard drives, hot-plug redundant power, ECC memory, dual internal SD module iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash iDRAC6 Express, BMC, IPMI 2.0, Dell OpenManage™ Optional: iDRAC6 Enterprise, vFlash 2 PCIe x8 G2 2 PCIe x8 + 2 PCIe x4 G2 or 1 x PCIe x16 + 2 PCIe x4 G2 5 PCIe x8 + 2 PCIe x4 PowerEdge R710 Technical Guide 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63

Dell
PowerEdge R710 Technical Guide
9
Feature
R610
R710
R810
Drive Bays
6 x
2.5‖
4 x 3.5" with optional
flex bay,
6 x 3.5" without flex
bay, or
8 x 2.5
6 x 2.5‖
Hard Drive Types
Hot-plug SAS and
SATA, nearline SAS
and SSD
Hot-plug SAS and
SATA, nearline SAS
and SSD
Hot-plug SAS and
SATA, SATA SSD
External Drive
Bay(s)
Optional internal
SATA slimline optical
drives such as DVD-
ROM or DVD+RW
Optional flex bay
expansion to support
half-height tape
backup unit
N/A
Embedded Hard
Drive Controller
PERC 6/i, SAS 6/iR,
PERC H200, PERC
H700
PERC 6/i, SAS 6/iR,
PERC H200, PERC
H700
PERC H200, PERC
H700
Optional Storage
Controller
Non-RAID:
SAS 5/E
LSI 2032 (for tape
backup unit only)
6Gps SAS HBA
RAID:
SAS 6/iR
PERC 6/i
PERC 6/E
PERC H200
PERC H700
PERC H800
Non-RAID:
SAS 5/E
LSI 2032 (for tape
backup unit only)
6Gps SAS HBA
RAID:
SAS 6/iR
PERC 6/i
PERC 6/E
PERC H200
PERC H700
PERC H800
Non-RAID:
SAS 5/E
LSI 2032 (for tape
backup unit only)
6Gps SAS HBA
RAID:
PERC H200
PERC H700
PERC H800
Availability
Hot-plug hard drives,
hot-plug redundant
power and cooling,
ECC memory,
Single Device Data
Correction (SDDC),
memory demand and
patrol scrubbing,
high-availability
failover cluster
Hot-plug hard drives,
hot-plug redundant
power and cooling,
ECC memory,
Single Device Data
Correction (SDDC),
memory demand and
patrol scrubbing,
high-availability
failover cluster
Hot-plug hard
drives,
hot-plug redundant
power,
ECC memory,
dual internal SD
module
Server
Management
iDRAC6 Express, BMC,
IPMI 2.0, Dell
OpenManage™
Optional: iDRAC6
Enterprise, vFlash
iDRAC6 Express,
BMC, IPMI 2.0, Dell
OpenManage™
Optional: iDRAC6
Enterprise, vFlash
iDRAC6 Express,
BMC, IPMI 2.0, Dell
OpenManage™
Optional: iDRAC6
Enterprise, vFlash
I/O Slots
2 PCIe x8 G2
2 PCIe x8 + 2 PCIe x4
G2 or
1 x PCIe x16 + 2 PCIe
x4 G2
5 PCIe x8 + 2 PCIe
x4