Dell S5248F-ON VxFlex Network Deployment Guide using EMC Networking 25GbE swit - Page 20
Verify switch configuration - port group
![]() |
View all Dell S5248F-ON manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 20 highlights
S5248-Leaf1A(config)# interface range ethernet 1/1/1-1/1/4 S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# no ip address S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# description "LINK TO VXFLEX NODES" S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# mtu 9216 S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# switchport mode trunk S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# switchport access vlan 1 S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# switchport trunk allowed vlan 1632,1633,1634 S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# spanning-tree port type edge S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# spanning-tree guard root S5248-Leaf1A(conf-range-eth1/1/1-1/1/4)# no shut The following mode command converts 25GbE switch ports to 10GbE, allowing 10GbE network devices to attach to the 25GbE switch at the lower speed. The converted port's new port names end in :1. S5248-Leaf1A(config)# port-group 1/1/12 S5248-Leaf1A(conf-pg-1/1/12)# mode Eth 10g-4x S5248-Leaf1A(conf-pg-1/1/12)# exit Save the configuration. S5248-Leaf1A(config-line-vty)# end S5248-Leaf1A# write memory Note: IP configuration for VLAN IDs 1634 (on Leaf1A) and 1635 (on Leaf1B) is optional. A gateway is not required for the two VxFlex data networks. When connecting external SDC's it is recommended to use IP's on the same subnet. Connecting SDC's via router on a different subnet is supported and will require manual configuration of static routes on the SVM and the ESXi as described in Appendix B. 4.3 Verify switch configuration The following sections provide the commands and outputs that are used to verify the configuration of the switches, and to ensure that they are correctly connected. Except where there are fundamental differences, the only output that is shown is the S5248F-Leaf1A switch. The output from S5248F-Leaf1B is similar. 4.3.1 show vlt domain id The show vlt domain-id command validates the VLT configuration status when the VLTi Link Status is up. The role of one switch in the VLT pair is primary (shown) and its peer switch is assigned the secondary role. The Inter-chassis link (ICL) Link Status, Heart Beat Status, and VLT Peer Status must all be up. The role of one switch in the VLT pair is Primary, and its peer switch (not shown) is assigned the Secondary role. Peer routing is also enabled leaving timers at system defaults. S5248-Leaf1A# show vlt 1 Domain ID Unit ID Role Version Local System MAC address Role priority : 1 : 1 : primary : 2.0 : 54:bf:64:e6:dd:c1 : 1 20 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE
![](/manual_guide/products/dell-powerswitch-s3048on-vxflex-network-deployment-guide-using-emc-networking-25gbe-switches-os10ee-4c6eb70/20.png)