Dell S5248F-ON VxFlex Network Deployment Guide using EMC Networking 25GbE swit - Page 7

Attachments, Dell EMC VxFlex

Page 7 highlights

1.2 1.3 Attachments This document in .pdf format includes one or more file attachments. To access attachments in Adobe Acrobat Reader, click the icon in the left pane halfway down the page, then click the icon. Dell EMC VxFlex A VxFlex virtual SAN consists of the following software components: • Meta Data Manager (MDM) - Configures and monitors the VxFlex system. The MDM can be configured in redundant cluster mode, with three members on three servers, or five members on five servers. The example in this guide creates a three-member MDM configuration. • Storage Data Server (SDS) - Manages the capacity of a single server and acts as a back-end for data access. In this guide, all servers act as an SDS. • Storage Data Client (SDC) - A lightweight device driver that exposes VxFlex volumes as block devices. In this guide, all servers act as an SDC. In this environment, the VxFlex/ScaleIO Virtual Machine (SVM) hosts the MDM and SDS roles. Each VxFlex node, running ESXi, has a separate SVM. The following illustration shows the communication between these components: VxFlex component communication 7 VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

7
VxFlex Network Deployment Guide using Dell EMC Networking 25GbE switches and OS10EE
1.2
Attachments
This document in .pdf format includes one or more file attachments. To access attachments in Adobe Acrobat
Reader, click the icon in the left pane halfway down the page, then click the
icon.
1.3
Dell EMC VxFlex
A VxFlex virtual SAN consists of the following software components:
Meta Data Manager (MDM) - Configures and monitors the VxFlex system. The MDM can be
configured in redundant cluster mode, with three members on three servers, or five members on five
servers. The example in this guide creates a three-member MDM configuration.
Storage Data Server (SDS) - Manages the capacity of a single server and acts as a back-end for data
access. In this guide, all servers act as an SDS.
Storage Data Client (SDC) - A lightweight device driver that exposes VxFlex volumes as block
devices. In this guide, all servers act as an SDC.
In this environment, the VxFlex/ScaleIO Virtual Machine (SVM) hosts the MDM and SDS roles. Each VxFlex
node, running ESXi, has a separate SVM. The following illustration shows the communication between these
components:
VxFlex component communication