Denon AVR2307CI Owners Manual - English - Page 15

Fenter Fenter - connections

Page 15 highlights

ENGLISH Easy Setup Procedure y Starting Auto Setup Press D H to select "Start", then press F. • Start the measurements. Measurement of each channel is performed as follows: FL FR 1 2 C SW SL SR SBL SBR 1: The subwoofer speaker is measured twice. 2: Not displayed when "ZONE2" and "Front" are set at "Setting the Power Amplifier Assignment" ( page 58). • After each channel is measured, "Calculating" appears. • The display switches to the Auto Setup check screen automatically. e Cautions during measurements: • Loud test tones are output during the measurements. Be careful for example when small children are nearby. • Proper measurements may not be possible if there are obstacles between the speaker and the setup microphone. • During the measurements, do not stand between or near the speakers and setup microphone. • To avoid influencing the measurements, turn off the power of air- conditioners or any other equipment producing sound in the room. Perform the measurements with the room as quiet as possible. • Measurement is cancelled when VOLUME is operated while the Auto Setup is performed. ¢ About automatic retry To confirm the results of the measurements, remeasurement is automatically performed. Remeasurement is performed up to two times. During this time, "Retry1" or "Retry2" is displayed on the screen. Easy Setup Procedure u Checking and storing the measurement results 1 Press D H to select an item, then press ENTER. The measurement results of each item can be checked here. 2 After checking, press ENTER, then press D H to set. Store: All the settings are stored in the memory. Retry: Perform the measurement again. Measurement is repeated. Cancel: Cancel the auto setup settings. 3 When "Store" is selected: Press F. 1 NOTE: • Do not change the speaker connections or subwoofer volume after making the measurements. • Do not turn off the power while the data is being stored. h (Press ENTER.) 2 12 ENGLISH Example: Speaker Configuration Check • When measurements have been made using the measurement microphone, speakers with a built-in filter such as subwoofers might be set with a value that differs from the physical distance because of the internal electrical delay.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82

ENGLISH
ENGLISH
Easy Setup Procedure
Easy Setup Procedure
12
u
Checking and storing the measurement
results
Press
DH
to select an item, then press
ENTER
.
The measurement results of each item can be checked here.
1
After checking, press
ENTER
, then press
DH
to set.
2
When “Store” is selected:
Press
F
.
3
• When measurements have been made using the measurement
microphone, speakers with a built-in filter such as subwoofers might
be set with a value that differs from the physical distance because
of the internal electrical delay.
Retry:
Perform the measurement again.
Measurement is repeated.
Store:
All the settings are stored in the memory.
Cancel:
Cancel the auto setup settings.
¢
About automatic retry
To confirm the results of the measurements, remeasurement is
automatically performed.
Remeasurement is performed up to two times. During this time,
“Retry1” or “Retry2” is displayed on the screen.
NOTE:
• Do not change the speaker connections or subwoofer volume
after making the measurements.
• Do not turn off the power while the data is being stored.
Cautions during measurements:
• Loud test tones are output during the measurements. Be careful
for example when small children are nearby.
• Proper measurements may not be possible if there are obstacles
between the speaker and the setup microphone.
• During the measurements, do not stand between or near the
speakers and setup microphone.
• To avoid influencing the measurements, turn off the power of air-
conditioners or any other equipment producing sound in the
room. Perform the measurements with the room as quiet as
possible.
• Measurement is cancelled when
VOLUME
is operated while the
Auto Setup is performed.
y
Starting Auto Setup
Press
DH
to select “Start”, then press
F
.
• Start the measurements.
Measurement of each channel is performed as follows:
FL
FR
C
SW
SL
SR
SBL
SBR
1
2
1:
The subwoofer speaker is measured twice.
2:
Not displayed when “ZONE2” and “Front” are set at “Setting the
Power Amplifier Assignment” (
page 58).
• After each channel is measured, “Calculating” appears.
• The display switches to the Auto Setup check screen
automatically.
1
2
h
(Press
ENTER
.)
e
Example:
Speaker Configuration Check