Denon DN X1700 Owners Manual - Page 7

Part Names and Functions - midi

Page 7 highlights

Getting Started Connections Basic Operations Effector Function Fader Start USB Utility Specifications Troubleshooting Part Names and Functions For further details on the functions and other aspects of the parts, refer to the page numbers in parenthesis. Top Panel E1 E3 E2 E5 R1 R2 R3 q w E0 e W9 r W8 t y E4 W7 E6 E7 W6 E8 W5 u W4 i o W3 Q0 W2 Q1 W1 W0 Q2 Q3 Q9 Q4 Q8 Q5 R0 Q7 Q6 E9 q MASTER LEVEL control Adjusts the level of the MASTER outputs. The LIMITER LED indicates the operating status of the master output limiter. • Limiter OFF: LED is off. • Limiter ON: LED lights up green. • While limiter is operating: LED lights up red. w Master EFX INS 1, 2 buttons These buttons enable the various effects of the selected side, either EFX 1 or EFX 2, to be obtained for the master output signals. e BOOTH LEVEL control Adjusts the level of the BOOTH outputs. r USB ASSIGN CH/MASTER button This is used to switch the assignment destination of the USB audio input signals supplied from the computer. CH: The signals are assigned to the channels (1 to 4). MASTER: The signals are assigned to the master bus and monitor bus. t MIDI CLOCK START/STOP button This enables the MIDI clock corresponding to the BPM value to be sent from the USB MIDI and MIDI output terminals to the computer (software) or external device. START: Sending the MIDI clock is started. STOP: Sending the MIDI clock is stopped. y UTILITY/-USB A/USB B button This allows the presets to be set and the system information to be set, changed or referenced. When it is held down for more than a second, the USB mode switching screen is opened, and the USB device mode or USB host mode can be selected. u BEAT , buttons (Short) : The beat/time is decreased. (Long) : The beat/time is increased. i TAP LOCK/AUTO/INPUT BPM button TAP: When this button is tapped repeatedly, the BPM (Beats Per Minute) value is measured using the intervals between the taps. LOCK: When the button is pressed once in the auto BPM mode, the BPM value measured automatically is locked. AUTO BPM: When the button is held down for one second, the auto BPM mode is established, and the measured BPM value is displayed. INPUT BPM: When it is held down for two or more seconds, the BPM input mode is established, and the BPM value can be input directly using the u BEAT , buttons. When it is pressed again, the mode is released. o TIME/BACK button TIME: This button is used to select whether to change the effects produced using the u BEAT , buttons on the basis of the number of beats or time. BACK (EFX 2 side only): This is used when returning to the previous screen while setting screen operations are being performed. Q0 Effect CUE button When this button is set to ON, the sound of the effects (but not the DELAY, ECHO or REVERB effects) can be monitored even if the effect OFF status. Q1 EFX SELECT control This is for selecting the effect to be used. Refer to the effect functions (page 9). Q2 Parameter ON/OFF button This is used to control the ON and OFF settings of the effect parameters. Q3 PARAMETER MIX/MAX control This is used to adjust the filter cutoff frequency and other effector parameters. The parameters are changed by the effector selected. Q4 DRY/WET control Use this to adjust the ratio of original and effected sound. 3

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26

3
Getting Started
Connections
Basic Operations
Specifications
Troubleshooting
Effector Function
Fader Start
Utility
USB
Part Names and Functions
For further details on the functions and other aspects of the parts, refer to the page numbers in
parenthesis.
Top Panel
R
3
E
0
W
9
W
8
W
7
W
6
W
3
W
4
W
1
Q
9
W
0
Q
8
Q
7
Q
6
E
9
R
0
Q
4
Q
5
Q
3
Q
2
Q
0
Q
1
u
i
o
E
8
r
y
E
6
e
w
q
R
2
R
1
E
5
E
2
E3
E
1
E
4
t
W
2
W
5
E
7
q
MASTER LEVEL control
Adjusts the level of the MASTER outputs.
The LIMITER LED indicates the operating status
of the master output limiter.
• Limiter OFF: LED is off.
• Limiter ON: LED lights up green.
• While limiter is operating: LED lights up red.
w
Master EFX INS 1, 2 buttons
These buttons enable the various effects of
the selected side, either EFX 1 or EFX 2, to be
obtained for the master output signals.
e
BOOTH LEVEL control
Adjusts the level of the BOOTH outputs.
r
USB ASSIGN CH/MASTER button
This is used to switch the assignment destination
of the USB audio input signals supplied from the
computer.
CH:
The signals are assigned to the channels (1 to 4).
MASTER:
The signals are assigned to the master bus and
monitor bus.
t
MIDI CLOCK START/STOP button
This enables the MIDI clock corresponding to
the BPM value to be sent from the USB MIDI
and MIDI output terminals to the computer
(software) or external device.
START:
Sending the MIDI clock is started.
STOP:
Sending the MIDI clock is stopped.
y
UTILITY/–USB A/USB B button
This allows the presets to be set and the system
information to be set, changed or referenced.
When it is held down for more than a second,
the USB mode switching screen is opened, and
the USB device mode or USB host mode can
be selected.
u
BEAT
,
buttons
(Short) :
The beat/time is decreased.
(Long) :
The beat/time is increased.
i
TAP LOCK/AUTO/INPUT BPM button
TAP:
When this button is tapped repeatedly, the BPM
(Beats Per Minute) value is measured using the
intervals between the taps.
LOCK:
When the button is pressed once in the auto BPM
mode, the BPM value measured automatically is
locked.
AUTO BPM:
When the button is held down for one second,
the auto BPM mode is established, and the
measured BPM value is displayed.
INPUT BPM:
When it is held down for two or more seconds,
the BPM input mode is established, and the
BPM value can be input directly using the
u
BEAT
,
buttons. When it is pressed
again, the mode is released.
o
TIME/BACK button
TIME:
This button is used to select whether to change
the effects produced using the
u
BEAT
,
buttons on the basis of the number of beats
or time.
BACK (EFX 2 side only):
This is used when returning to the previous
screen while setting screen operations are
being performed.
Q
0
Effect CUE button
When this button is set to ON, the sound of the
effects (but not the DELAY, ECHO or REVERB
effects) can be monitored even if the effect OFF
status.
Q
1
EFX SELECT control
This is for selecting the effect to be used.
Refer to the effect functions (page 9).
Q
2
Parameter ON/OFF button
This is used to control the ON and OFF settings
of the effect parameters.
Q
3
PARAMETER MIX/MAX control
This is used to adjust the filter cutoff frequency
and other effector parameters. The parameters
are changed by the effector selected.
Q
4
DRY/WET control
Use this to adjust the ratio of original and
effected sound.
Getting Started