English • Unattended operation of this product could result in personal injury or property damage. To reduce the risk of fire, do not allow the compressor to operate unattended. • Always remain in attendance with the product when it is operating. • Always disconnect electrical power by moving the On/ Off switch in the OFF position and drain tank daily or after each use. DANGER: RISK TO BREATHING (Asphyxiation) What can happen How to prevent it • The compressed air directly from your compressor is not safe for breathing. The air stream may contain carbon monoxide, toxic vapors, or solid particles from the air tank. Breathing these contaminants can cause serious injury or death. • Never use air obtained directly from the compressor to supply air for human consumption. The compressor is not equipped with suitable filters and in-line safety equipment for human consumption. • Exposure to chemicals in dust created by power sanding, sawing, grinding, drilling, and other construction activities may be harmful. • Sprayed materials such as paint, paint solvents, paint remover, insecticides, weed killers, may contain harmful vapors and poisons. • Work in an area with good cross ventilation. Read and follow the safety instructions provided on the label or safety data sheets for the materials you are spraying. Always use certified safety equipment: NIOSH/OSHA respiratory protection or properly fit­ting face mask designed for use with your specific application. WARNING: RISK of Bursting Air Tank: On February 26, 2002, the U.S. Consumer Product Safety Commission published Release # 02-108 concerning air compressor tank safety: Air compressor receiver tanks do not have an infinite life. Tank life is dependent upon several factors, some of which include operating conditions, ambient conditions, proper installations, field modifications, and the level of maintenance. The exact effect of these factors on air receiver life is difficult to predict. If proper maintenance procedures are not followed, internal corrosion to the inner wall of the air receiver tank can cause the air tank to unexpectedly rupture allowing pressurized air to suddenly and forcefully escape, posing risk of injury to consumers. Your compressor air tank must be removed from service by the end of the year shown on your tank warning label. The following conditions could lead to a weakening of the air tank, and result in a violent air tank explosion: 4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

4
English
• Unattended operation of
this product could result in
personal injury or property
damage. To reduce the risk
of fire, do not allow the
compressor to operate unat-
tended.
• Always remain in attendance
with the product when it is
operating.
• Always disconnect electrical
power by moving the
On/ Off
switch in the OFF position
and drain tank daily or after
each use.
DANGER: RISK TO BREATHING (ASPHYXIATION)
WHAT CAN HAPPEN
HOW TO PREVENT IT
• The compressed air directly
from your compressor is not
safe for breathing. The air
stream may contain carbon
monoxide, toxic vapors,
or solid particles from the
air tank. Breathing these
contaminants can cause
serious injury or death.
• Never use air obtained directly
from the compressor to supply
air for human consumption. The
compressor is not equipped
with suitable filters and in-line
safety equipment for human
consumption.
Exposure to chemicals
in dust created by
power sanding, sawing,
grinding, drilling, and other
construction activities may
be harmful.
Sprayed materials such as
paint, paint solvents, paint
remover, insecticides, weed
killers, may contain harmful
vapors and poisons.
Work in an area with good
cross ventilation. Read and
follow the safety instructions
provided on the label or safety
data sheets for the materials
you are spraying. Always use
certified safety equipment:
NIOSH/OSHA respiratory
protection or properly fitting
face mask designed for use
with your specific application.
WARNING: RISK OF BURSTING
Air Tank:
On February 26, 2002, the U.S. Consumer Product
Safety Commission published Release # 02-108 concerning air
compressor tank safety:
Air compressor receiver tanks do not have an infinite life. Tank life
is dependent upon several factors, some of which include operating
conditions, ambient conditions, proper installations, field modifica-
tions, and the level of maintenance. The exact effect of these fac-
tors on air receiver life is difficult to predict.
If proper maintenance procedures are not followed, internal corro-
sion to the inner wall of the air receiver tank can cause the air tank
to unexpectedly rupture allowing pressurized air to suddenly and
forcefully escape, posing risk of injury to consumers.
Your compressor air tank must be removed from service by the end
of the year shown on your tank warning label.
The following conditions could lead to a weakening of the air tank,
and result in a violent air tank explosion: